C762, C764, C764i Stairclimber
Page 26
THEN...
OTHERWISE...
The original upper ribbon cable is
The original upper ribbon cable is not
bad; install a new cable as described
bad; continue with the next step.
in Procedure 7.10.
18. Support the display housing while you connect the original upper ribbon cable to the upper
PCA.
19. Connect the original upper and lower ribbon cables to each other.
20. Line up the tabs on the display housing with the tab holes on the display base
plate.
21. Gently press the display housing onto the display base plate until the tabs are pushed into
the holes on the base plate.
22. Replace the screws that secure the display housing to the display base plate.
Note:
Gently push any excess cable into the column.
23. Slide the enclosure collar down the column and over the column mounting screws. Press
down to ensure a snug fit.
24. Slide the power entry module into the climber. Using the screwdriver, install the two screws
that secure the power entry module to the climber frame.
25. Check the operation of the climber as described in Section Four.
Summary of Contents for Cardio Theater Integrated Bracket C764i