C762, C764, C764i Stairclimber
Page 58
Procedure 7.11 - Replacing the Remote Sensor Assembly
Removing the Remote Sensor Assembly
1.
Remove the covers as described in Procedure 7.1.
WARNING
Before continuing with this procedure, review the Warning and Caution statements listed in
Section One, Things You Should Know.
2.
Remove the remote sensor cable from the lower PCA.
Note:
The cable clips hold the remote sensor cable away from moving components on the climber.
3.
Remove the remote sensor cable from the cable clips mounted on the climber frame.
4.
Remove the fasteners that secure the remote sensor to the disk bracket.
5.
Remove the remote sensor assembly from the disk bracket.
Replacing the Remote Sensor Assembly
6.
Position the remote sensor assembly on the disk mounting bracket. Make sure that the
remote sensor assembly tabs straddle the target (see Diagram 7.6).
7.
Install the fasteners that secure the remote sensor to the disk bracket.
Note:
The plain washer must be mounted next to the disk bracket.
8.
Route the remote sensor cable through the cable clips mounted on the climber frame.
CAUTION
The remote sensor cable must not come in contact with moving components.
9.
Connect the remote sensor cable to the lower PCA.
10. Check the operation of the climber as described in Section Four, then replace the covers as
described in Procedure 7.1.
Summary of Contents for Cardio Theater Integrated Bracket C764i
Page 23: ...C762 C764 C764i Stairclimber Page 23 Diagram 5 3 Magnet Wiring ...
Page 61: ...C762 C764 C764i Stairclimber Page 61 Diagram 7 7 Magnet Wiring ...
Page 100: ...C762 C764 C764i Stairclimber Page 100 Wiring Diagram 8 1 C762 C764 120 Vac ...
Page 101: ...C762 C764 C764i Stairclimber Page 101 Block Diagram 8 2 C762 C764 120 Vac ...
Page 102: ...C762 C764 C764i Stairclimber Page 102 Wiring Diagram 8 3 C762 C764 240 Vac ...
Page 103: ...C762 C764 C764i Stairclimber Page 103 Block Diagram 8 4 C762 C764 240 Vac ...