©2011 Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law
Troubleshooting 3.32 - P80 Machine Controls Unresponsive
Description
Machine controls do not respond to input. User is unable to change workout parameters.
Possible Causes
1.
Cable from machine controls to upper board is damaged or not inserted properly.
2.
Machine controls have failed
Possible Remedies
1.
Check yellow/black cable in console for damage. Ensure the cable is inserted fully onto the pins. If not
inserted properly, insert. If cable is damaged, console must be replaced; this is not a replaceable part.
2.
If machine controls have failed, the entire console will need to be replaced. This is not a replaceable part.