Procedure 6.4 - Troubleshooting the Eddy Current System
Note:
If the control circuit does not see an output from the speed sensor, it removes power from the
eddy current system. Therefore, when it is necessary to check the pedaling resistance or take
voltage measurements in the eddy current system it will be necessary to slowly turn the flywheels
to ensure that the power time out has not occurred.
WARNING
Before continuing with this procedure, review the Warning and Caution statements listed in
Section One, Things You Should Know
1.
Remove the upper, right and left rear covers per Procedure 7.1. There are four typical
symptoms concerning the eddy current system. No resistance (pedaling resistance), no
resistance shortly after power up, incorrect resistance and error 50. If the problem is no
resistance, continue with step 2. If the problem is no resistance shortly after power up, test
the speed sensor per Procedure 6.3. If the problem is incorrect resistance, skip to step 7. If
the problem is an error 50, skip to step 10.
2.
Set the on/off switch in the “on” position, enter the manual program and set the resistance at
level 10. Using a DC voltmeter, check the voltage across the magnet wires at the lower PCA
(J1-1 & J1-2). The voltage should measure approximately 25 Vdc. If the voltage is missing
or significantly low, continue with step 3.
3.
Set the on/off switch in the “off” position. Using an ohmmeter, measure between the magnet
wires at the lower PCA. The measurement should be approximately 90
Ω
to 110
Ω.
If the
measurement is open (
∞
), check the connections at both magnets and the lower PCA and
the wires between the lower PCA and the magnets. The lower PCA to magnet wires must
read less than 1
Ω
when measured from end to end with an ohmmeter. Check the EFX per
Section Four.
4.
If all of the wiring connections are good and there is still no resistance, there are two parts
that could cause the problem. There are not any good tests to check these parts other than
substituting a known good part. They are lower PCA and upper PCA. Replace only one part
at a time. If the new part does not correct the problem re-install the original part.
5.
If you have performed all of the above tests and there is still no resistance, call Precor
Technical Support.
6.
If the resistance is greater than normal, the cause could be mechanical rather than
electrical. Set the on/off switch in the off position and test the unit by checking all moving
parts in the drive section and stairarms for worn parts that could be “binding”. Replace the
appropriate parts.
Summary of Contents for EFX EFX 5.23
Page 79: ...Block Diagram 8 2 5 23 5 25...