Procedure 7.17 - Replacing a Stairarm
Warning:
Care must be taken when work is being performed in the area of the stairarms. Pinch
points exist between the stairarm and ramp and between the stairarm and crankarm,
when the rear covers are removed.
Procedure
1.
Set the on/off switch in the “off” position, then unplug the power cord from the wall outlet.
WARNING
Before continuing with this procedure, review the Warning and Caution statements listed in
Section One, Things You Should Know.
2.
Remove the left or right cover sections, as required, as described in Procedure 7.1.
3.
5.25 only.
Remove the bolt that fasten the stairarm link to the stairarm. See Diagram 7.12.
Diagram 7.12 - 5.25 Stairarm Link
4.
Remove the mounting bolt and nut that fastens the stairarm pivot block to the stairarm. See
Diagram 7.9.
5.
Slide the stairarm off of the stairarm pivot block.
6.
Roll the stairarm out of the rear of the ramp.
7.
Remove and stairarm pedal from the existing stairarm and install it on the replacement
stairarm per Procedure 7.16.
8.
Remove and stairarm wheel from the existing stairarm and install it on the replacement
stairarm per procedure 7.15
9.
Roll the stairarm into the ramp channel from the rear of the ramp.
Stairarm
Link
Mounting
Bolt
Summary of Contents for EFX EFX 5.23