Press
Enter
once again and the
Error Log
appears. The EFX stores the last ten
errors that have been detected. Press any
▼
or
▲
key to view the error codes.
Note
: If the EFX has no errors stored in memory, a “– – –” appears on the display.
To
view
the odometer reading at the time the error was detected and the hours of use
at the time the error occurred, press the
Select
key while the error code is being
displayed. The
Select
key acts as a toggle between the associated information.
To
clear
(delete) the error log, press
QuickStart
for at least four seconds while
viewing the list. Prompts appear on the display and confirm (OK) that the error
messages have been deleted (“cleared”) from memory.
Important
: You cannot retrieve the error log once you have deleted it.
USING CSAFE STANDARD EQUIPMENT
The EFX is fully compatible with CSAFE protocols. Once the unit is connected to
a CSAFE master device and the user maintains a stride rate above 40 strides per
minute, he or she is prompted to enter an identification number (user ID).
Note
: If the optional battery recharger is plugged into the EFX and connected to
an appropriate power source, then no pedaling is necessary for user ID entry.
Five zeros appear on the display. The left zero indicates that it is awaiting input.
The following table provides information about the keypad functions:
User ID Entry:
Program Keys
▼
or
▲
moves the blinking LED from field to field.
Enter
submits the displayed user ID. Note that if the five zeros
are being displayed when the user presses
Enter
, the user
ID entry is bypassed and the
Course
prompt appears.
Reset
resets the display to the Precor banner.
A message indicates when the user ID is accepted by the CSAFE master device.
Then, the course prompt is displayed. See
Quick Steps to Working Out on page 39.
Note
: If the user’s stride rate drops below 40 strides per minute while using the
CSAFE device connection, a prompt PEDAL FASTER appears. If the stride rate
remains below the 40 strides per minute threshold for the next twenty seconds,
the CSAFE connection is terminated. The word RESETTING appears on the
display while the EFX disconnects from the CSAFE device.
To review information about CSAFE specifications, visit the web site at:
www.fitlinxx.com/csafe
Note:
The EFX supports the CSAFE master device per the specifications found
at the web site. However, exceptions do exist. If you have questions or need
technical support, refer to
Obtaining Service on page 7.