1. Wipe down equipment using a soft lint-free cloth using only the recommended clean-
ing solution. Always spray cleaning solution directly onto the cleaning cloth and not
directly onto the equipment surface to avoid equipment damage due to excessive
moisture.
CAUTION
: Do not use acidic cleaners and do not spray directly onto the equipment
surfaces.
2. Rinse surfaces using a clean lint-free cloth dampened with water only.
3. Then completely dry with another clean lint-free cloth.
Power Requirements
Equipment Power Requirements
Electrical Recommendation for 120 V and 240 V Treadmills.
Note
: This is a recommendation only. NEC (National Electric Code) guidelines or
local region electric codes must be followed.
The facility must provide a good quality stable power signal (not fluctuating or intermittent)
per the OEM power requirements to insure best performance and trouble free operation.
Power Specification
l
Nominal 120
VAC
1
models
o
Operating voltage: 90 VAC to 132 VAC.
o
AC frequency range: 47 - 65
Hz
2
o
20 amp individual branch circuit
l
Nominal 240 VAC Models
o
Rated Operating voltage: 180 VAC - 264 VAC.
o
Frequency: 47- 65 Hz
o
20 amp individual branch circuit
Treadmill Grounding
The treadmill must be grounded. If the equipment malfunctions or breaks down, grounding
draws off electric current and reduces the risk of electric shock. The power cord on the
1
voltage in an alternating current circuit
2
The hertz (symbol: Hz) is the derived unit of frequency in the International System of Units
(SI) and is defined as one cycle per second.
Contact Precor Customer Support at support@precor.com or 800.786.8404 with