sure whether the equipment is properly grounded. DO NOT modify the plug
provided with the treadmill. If the plug does not fit the outlet, have a proper outlet
installed by a qualified electrician.
Verifying 20 Amp outlet receptacles
US and Canadian installations require 20A current rated power outlets.
You can visually identify a 20A from a 15A rated outlet receptacle by the different style outlet
sockets. Make sure the facility wall outlets are the 20A style outlet receptacles.
CAUTION
: DO NOT use 20A to 15A power cord adapters to plug the equipment
power cord into a 15A wall outlet.
20 Amp rated plugs and outlets
Country
Equipment Voltage
Receptacle/
Plug
1
Type
US & Canada
120 VAC: 50/60 Hz
Dedicated 120V/20A circuit with 5-20R
NEMA receptacle
US & Canada
240 VAC: 50/60 Hz
Dedicated 220V- 240V/20A circuit with 6-
20R NEMA receptacle
International
240VAC
IEC 320-C19 inlet supporting applicable
country-specific power cord
1
Device power cord connector or electrical cable male connector that is inserted into an
electrical receptacle "outlet" (also called the plug-in).
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
Page 17
2 General Information
Equipment Power Requirements