5. Remove the one #2 Phillips screw fastener and
LPCA
1
/Battery module cover. Dis-
connect the Generator input cable (J1) and Eddy/Brake load cable (J7) from the LPCA
board. Retain part(s) and/or fastener(s) for installation.
6. Use a 1/2" socket to loosen the two Generator/Eddy Brake assembly carriage bolt nuts
and the two Drive Components assembly carriage bolt nuts (left side). Do not remove
the fastener nuts.
1
Lower printed circuit assembly; generally this refers to the lower board. On treadmills, this is
the motor controller unit (MCU), and on self-powered units, it is the main board in the lower
section.
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
Page 97
6 Replacement Procedures
Generator/Eddy Brake assembly Replacement