7. Use a 1/2" socket to remove the two carriage bolt fasteners to separate the Gen-
erator/Eddy Brake assembly from the Step-up Pulley/Tensioner Assembly.
Installation Instructions
1. Place the Generator/Brake assembly onto the Step-up pulley/Tensioner assembly.
Secure using the two carriage bolts and nuts. Tighten the bolts just enough to keep the
carriage bolt heads inserted into the bolt belt adjustment slots to allow movement. Do
not fully tighten.
2. Use a 1/2" socket to install the second stage belt tension hardware: the tensioner adjust-
ment bolt, washer, and tug plate. Tighten the tensioner bolt just enough to keep the ten-
sioner hardware in place.
3. Reinstall the second stage drive belt by walking the belt onto the larger Step-up Pul-
ley/Tensioner pulley and Generator/Brake assembly pulley. Tighten the tensioner bolts
just enough to keep the belt on the pulleys and tensioner hardware in place. Do not fully
tension or over tension the belt.
4. Reinstall the Drive Components assembly, see
"Drive Components assembly Replace-
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
Page 107
6 Replacement Procedures
Step-up Pulley/Tensioner Assembly Replacement