11. Verify the lift motor calibration distance:
a. Access the diagnostic
CROSSRAMP TEST
and set the incline level to 10.
b. Measure and verify the Lift Motor calibration distance remains 9" +/- 1/4" (23 cm
+/- 0.6 cm.
12.
Select
QUICKSTART
and start a manual workout. Operate the machine at the fol-
lowing conditions to verify the Stairarm and ramp incline operation. Make sure that the
Stairarms and ramp movement is smooth and that there are no unusual noises:
l
. Set the
INCLINE
to 1 and operate the machine from 50 to > 150
SPM
.
l
Repeat this test at incline levels 10 and 20.
13. Reinstall the Ramp cover, the Lift Interface Plate cover, and the Front Lift cover, see
, and
14. Verify machine operation and return to service, see
.
Note
: This procedure may have generated lift motor related error codes. Check the
error log and resolve any active error codes, clear the error log on LED consoles.
See Also
"Lift Motor Calibration" on page 53
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
Page 131
6 Replacement Procedures
Lift Motor Replacement