l
Exercise program is the manual program.
l
Goal type is time.
l
Goal value is the club time limit.
l
All other exercise program parameters revert to default values appropriate to the spe-
cific exercise program.
l
Weight is 170 pounds or 77 kilograms.
l
Age, gender, target heart rate and fitness score are unknown.
l
Units, language, and optional metric are read from
EEPROM
1
, as set by Owner Set-
tings. Factory defaults for these are U.S., English, and no optional metric.
When the machine returns to Banner state after an exercise session ends, the following accu-
mulated session data is stored in memory until the system goes through the Initialization state,
or until the next user performs data entry.
l
Session program.
l
Session total time, including cool-down time.
l
Session total distance, including horizontal, vertical, strides, revolutions, equivalent dis-
tances, etc.
l
Session total calories.
l
Average speed.
l
Average heart rate, max heart rate, and total time spent in a heart rate zone.
l
Weight, age, gender, target heart rate, parameters related to interval course profile, and
fitness score.
System Component Overview
The EFX800-16 is comprised of two basic system blocks, the console and the base. The con-
sole provides the user input controls, metric indicator displays, and console-to-base com-
munication interfaces. The console also provide the service software menus including
maintaining the Error Log menu. The base receives machine operating commands and
executes them. The base also monitors error conditions and sends detected error code data to
the console.
1
Electrically erasable programmable read-only memory and is a type of non-volatile memory.
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
Page 201
9 Theory of Operation