DIAGNOSTIC TEST
TEST DESCRIPTION
"C" an external
AC
1
charger is connected.
"L" the battery is low (less than 11.5 Vdc).
"CL" charger is connected and the battery is low.
(1) Only included onl products that have the ASL feature.
(2) Not included on the EFX600 series or TRM600 series products.
Club Settings Menu (5651565)
Service Access Code: 5651565 (see
"Service Menu Access Codes" on page 17
)
menu:
Club Settings (51765761) > DIAGS - CLUB SETTINGS
CLUB SETTINGS
DESCRIPTION
SAFETY CODE
Enabled or disabled. When enabled, a user password (xxxx) is
required to use the machine.
Factory default: disabled.
SELECT
LANGUAGE
Sets the default language for all workouts on this machine. Lan-
guage for single use workouts can also be set by the user from the
workout options.
Default: English
SET UNITS
Sets units of measure to US standard or Metric.
Range: U.S, Metric
Default: U.S.
SET MAX
WORKOUT TIME
Sets the maximum allowable user workout time per session.
Range: 1 to 240 min, NO LIMIT
Default: 60 min
SET MAX PAUSE
TIME
Sets how long the equipment remains in a paused banner during
a workout before resetting.
Range: 1 to 120 sec (All except EFX)
Range: 1 to 60 sec (EFX only)
Default 30 sec.
1
Alternating Current: electric current which periodically reverses direction between positive
and negative polarity.
Contact Precor Customer Support at support@precor.com or 800.786.8404 with