Lift Motor Calibration
About
This procedure provides instruction to verify and calibrate the Lift Motor and Incline system.
The Lift Motor calibration should be verified anytime the Lift Motor fuse fails or is replaced or
any incline system component is replaced.
Specifications
System Component
Specification
Lift Motor Calibration Distance*
9" +/- 1/4" (23 cm +/- 0.6 cm
Yoke/Ramp Fasteners
330 in-lbs (27.5 ft-lbs or 37.2 Nm)
Note: * Calibration distance is set at incline level 10.
Procedure
Review entire procedure before starting.
TIP
: To help keep your hands clean while doing this procedure, it is advised to wear gen-
eral purpose mechanics gloves. You will be handling the jackscrew which is coated with
a thin layer of grease.
Lift Motor Calibration Verification
Contact Precor Customer Support at support@precor.com or 800.786.8404 with