Removal Instructions
This procedure will require a fully charged good battery to operate the lift motor.
IMPORTANT
: It's important to follow the removal steps in sequence to successfully
remove the ramp.
1. Remove the Lift Front cover (see
"Lift Front Cover Replacement" on page 72
) and Rear
Lift cover (see
"Lift Rear Cover Replacement " on page 77
).
2. Access the service menu diagnostic
CrossRamp Test
and raise the incline level to 10.
a. P10, P30, P30i and P31: (
Service menu (51765761)
>
MACHINE TEST
>
CROSSRAMP TEST
and raise the
INCLINE LEVEL
to 10).
b. P62, P80, and P82: (
Service menu (51765761)
>
System Settings
>
System
Tests
>
CrossRamp Test
and raise the
INCLINE
level to 10).
3. Disconnect the Lift Motor input power/control cable connector.
WARNING
: Make sure to disconnect the Lift Motor input power/control cable or it is
possible for the crossramp to automatically lower to level 1 under certain cir-
cumstances, such as, if the CrossRamp Test is exited or the console powers down.
This unexpected action could cause personal injury.
4. Remove the left and right Stairarms from the respective input Crank Spindle, see
arm Input Crank Removal" on page 199
. Repeat procedure for the left and right Stair-
arms.
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.