RBK 815 Recumbent Cycle
Page 45
Procedure 7.9 - Replacing the Secondary Pulley
1.
Remove the top, rear, left and right covers per procedure 7.1.
2.
Loosen, but do not remove the generator screws and tension bracket mounting
bolt, thread the tension adjustment bolt counter-clockwise to remove tension
from the secondary belt. See Diagram 7.13.
3.
Remove the retaining clip from the secondary axle. See Diagram 7.11.
Diagram 7.11 - Secondary Pulley
4.
Remove the plastic washer and the secondary pulley. Discard the secondary
pulley.
5.
Slide the replacement secondary pulley onto the secondary axle. Slide the plastic
washer, removed in step 4 onto the secondary axle. fasten the secondary pulley
with the retaining clip removed in step 4.
6.
Replace the secondary belt and tension it per Procedure 5.2.
7.
Replace the covers per procedure 7.1.
Secondary Pulley
Retaining Clip
Plastic Washer