On Chrono consoles, access the service mode and run any related tests that might help isolate
the cause of the issue, see
"Spinner® Chrono™ Console" on page 147
. These tests will also
help to identify good and failed components. Resolve any resulting failures.
6) Verify that there are no new error codes
After correcting the issue, use the equipment from minimum to maximum resistance and
speed ranges. Then stop pedaling and verify that the Error Log does not contain any new error
codes. . This will verify that the original error codes issues are fixed and that there are no new
error code issues.
Note
: If there is no logged error codes and the issue persists, you will need to use
observable and audible indicators to identify the source of the failure. Also make
sure that there are no related service bulletins that may resolve the issue. Go to Pre-
cor Connect website and browse the list of current service bulletins.
7) Verify service bulletins
Go to the Precor Connect website and browse the list of machine service bulletins and tech-
tips. Incorporate any missing service bulletin repairs and in particular any bulletins that may fix
the current failure.
123