IMPORTANT
: The resistance knob must be set to the minimum resistance level to
correctly perform the auto-cal function. The WATTS parameter will be incorrectly com-
puted if the resistance knob is not set to minimum resistance level during auto-cal.
b. Verify the measured WATTS at minimum and maximum resistance levels:
l
Set the resistance to minimum.
l
Start pedaling and maintain the speed at 60 rpm as reported on the con-
sole RPM. While continuously pedaling, verify the measured WATTS is
within spec at the minimum and maximum resistance levels. Continuously
pedal between measurements.
Resistance
Level
Power (WATTS)
minimum
≤ 40 Watts @ 60 rpm
maximum
≥ 415 Watts @ 60 rpm
Power (WATTS) specification
IMPORTANT
: The bike must be auto-cal'd before making the WATTS measurement.
Also, the bike must be continuously pedaled between the min and max resistance
WATTS measurements. If the pedals stop, a new auto-cal may occur invalidating the
measurements.
9. While riding the bike at 60 rpm, stop pedaling and firmly press down the resistance
knob. Verify that the flywheel immediately slows down and stops rotating.
10. Verify the bike operation per
"Operation Verification Checklist" on page 7
and return to
service.
See Also
"Adjustment Procedures" on page 10
15