6. Attach a cable puller (or fish tape) to the LPCA connector end of the cable.
7. Remove the cable from the inside of the right fork frame weldment. Pull from the top
access hole feeding both the cable and cable puller upward out of the frame. Dis-
connect the cable puller from the cable.
IMPORTANT
: Attach a cable puller (or fish tape) to the LPCA connector end of the
strain gauge cable before removing from the inside of the fork frame weldment. The
cable puller will be used to reinstall the cable through the frame.
1. Remove the two 4 mm hex key bolts (2x) and washers (2x) that secure the caliper
assemble to the frame and remove the caliper. Hold the caliper assembly while remov-
ing to prevent it from falling to the floor causing damage. Retain fastener hardware for
installation.
48
5 Replacement Procedures
Caliper Assembly Replacement