c. Secure both the data COMM and strain gauge cables to inside of the lower right
fork weldment using the lower push-mount-cable-tie.
3. Reinstall the flywheel which also reinstalls the LPCA board, the cross member, drive
belt, and generator belt, see
"Drive Belt, Generator Belt, and Flywheel Replacement"
4. Use a new cable tie to secure the data COMM and strain gauge cables to the top of the
flywheel axle bracket near the right fork weldment. If any one of the other three cable
ties are missing, replace them.
62
5 Replacement Procedures
Data COMM Cable Replacement