DIAGNOSTIC TEST
TEST DESCRIPTION
l
Nominal value: 242 ±5 @ 15% incline
Information Display (65)
menu:
Settings > Information
.
Service Access Code:
65
(see
)
The Information Display provides the equipment usage, hardware, software, error code,
and maintenance information:
INFORMATION DISPLAY
DESCRIPTION
Softkeys
Home
softkey
Select
Home
to exit and return to the Home page.
Error Log
softkey
Select
Error Log
to open the Error Log table, see .
Information Parameters
ODOMETER
The total number of accumulated miles (or kilometers) on
the unit.
This value is stored in the upper
PCA
1
in the console so if
the PCA is replaced the accumulated miles would start
again from "0".
USAGE
The total machine usage hours (hours : min).
This value is stored in the upper PCA in the console so if
that PCA is replaced the hours of use would start again
from "0".
SW Release P'N
The operating system software part number.
Hardware Version
Hardware version.
Console S/N
Console serial number.
LPCA
2
VersionSW
The LPCA software version.
uPA BOOT SW
The console upper boot software version information.
1
Printed circuit assembly, generally referred to as either an upper PCA or lower PCA.
2
Lower Printed Circuit Assembly board; also refered to as the Lower PCA or simply as the
lower board. On treadmills, it is the console to base function interface and the motor con-
troller unit (MCU). On self-powered units, it is the lower PCA console to base function inter-
face.
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
Page 30
4 Standard Service Menus
R40 Standard Service Menus