Lift Platform Replacement
This procedure provides instruction to remove and replace the Lift Platform.
Procedure
Review entire procedure before starting.
Removal
1. Switch the power "OFF" and unplut the power cord.
2. Remove the hood cover.
3. Lay the treadmill on its side.
4. Use tape to mark the location on the jackscrew were it enters the extension tube (This
marks the extension of the jackscrew which will be used when reinstalling the lift
motor). Then remove the hitch pin, spacers (2) and clevis pin that fasten the lift motor
extension tube to the lift platform.
Important:
While the lift tube is not fastened to the lift platform, care must be taken to
not allow the lift tube to rotate. If the lift tube rotates, the lift motor must be re-cal-
ibrated.
5.
6. While supporting the lift platform, remove right and left lift platform pivot hitch pins.
Carefully push the right and left clevis pins outward enough to allow the lift platform to
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
Page 83
6 Replacement Procedures
Lift Platform Replacement