© Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law
Page 42
Error 09 - Lower PCA Memory Test Errors
Description
Error 09 checks lower PCA memory locations during the power up test
sequence. If a fault is found during the power up test sequence, error 09
will be displayed. This error code is only used on products utilizing the
dual microprocessor system.
Possible Cause
This error message almost always indicates a lower PCA problem when it is
consistently displayed. Failures causing this error message to be
displayed are rare.
Possible Remedy
If the error message is consistently displayed when the unit is powered
up, the lower PCA should be replaced. It is possible to see this error
message displayed intermittently due to external causes. If the unit's
A.C. input significantly dips during the power up test sequence the test
could fail resulting in this message being displayed. Treadmills
operating on non-dedicated A.C. circuits may see this message displayed
on an intermittent basis.
Summary of Contents for TRM10/GEN06
Page 2: ......
Page 23: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 21...
Page 93: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 91...
Page 140: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 138...
Page 141: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 139...
Page 142: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 140...
Page 143: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 141...