Figure 14: Lower Control Module Connector Numbering
With the incline above 0% (to allow room for lift travel down),
connect an AC voltmeter between terminals 1 (white) & 5 (black)
of the INCLINE connector. Set the treadmill in the manual program
and press the INCLINE
key. The AC voltmeter should read AC line
voltage (either 120VAC or 240VAC). Note that the AC line voltage
reading will only be present before an error condition is
displayed. A correct reading here verifies that the DOWN triac
switch is working properly.
o
If either of these conditions fail, the lower control module
must be replaced
.
4
The lift capacitor mounted inside the lift motor. If the lift
capacitor is shorted (0 W), the lift fuse will blow. The capacitor
may be checked by disconnecting the lift motor connector from the
lower control module and using an ohmmeter to measure between pins 5
& 6 of the lift motor connector.
If the capacitor is open or leaky it cannot be determined with an
ohmmeter. A leaky capacitor functions normally for light users,
while failing to move the lift for heavier users. An open
capacitor will not function at all and cannot be determined by an
ohmmeter, so the following test will determine if the capacitor
is bad.
Summary of Contents for TRM10/GEN06
Page 2: ......
Page 23: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 21...
Page 93: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 91...
Page 140: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 138...
Page 141: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 139...
Page 142: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 140...
Page 143: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 141...