© Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law
Page 69
2
Set the treadmill’s speed at 7-8 m.p.h. and the incline at 0%. Walk
on the treadmill and observe the average A.C. current reading.
Typical average A.C. current readings on a new running belt and deck
are between 8 to 12 amperes. average readings (those read by a
digital meter) could be as high as 20 amps, even on a new belt and
deck.
3
If the average current reading approaches 20 amperes, the running
belt should be replaced. The running deck should be flipped or
replaced if the running deck has been previously flipped. See
Procedure,
Running Belt and/or Deck Replacement
belt and running deck replacement.
4
If the average AC current readings are greater than on a new running
belt and deck combination but not approaching 20 amperes, the
reading will give you an indication of the running belt and deck
combination’s general condition.
NOTE: Repeat the amp draw test after replacing a running belt
and deck.Damage to the lower control module can occur if the
unit had been run in an overload/high current condition for
prolonged periods of time. This type of damage would not
generate an error code, but would cause the breaker to trip
intermittently. An amp draw test will catch this condition.
Summary of Contents for TRM10/GEN06
Page 2: ......
Page 23: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 21...
Page 93: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 91...
Page 140: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 138...
Page 141: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 139...
Page 142: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 140...
Page 143: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 141...