Error 61 or “Temporarily Out of Order” – Auto Stop Not Present
Description
This error is associated with the TRM Treadmill. The error indicates
the Auto Stop sensor is not detected. If the error is detected the user
will be locked out, displaying "Temporarily Out of Order, Please Use
another treadmill" on the P80 console and "PLEASE USE ANOTHER
TREADMILL" on the P30 and P20 consoles. When this error occurs
"1376257-E_AUTOSTOP_SENSOR_NOT_INSTALLED" will be recorded to the event
log of the P80 console. Error 61 will be recorded in the error log of
the P10, P20 or 30 console.
Possible Causes
1
Intermittent connections.
2
Bad upper PCA or Console.
3
Bad Auto Stop cable.
4
Damaged or faulty Auto Stop sensor.
Possible Remedies
1
Visually verify the Auto Stop hardware components are installed onto
the treadmill frame. The Auto Stop feature was not on the TRM as a
standard feature until 12/28/2010 but may have shipped with a P80
console prior to 12/28/2010. If the Auto Stop hardware is not
present contact Precor Customer Support. Check that the Auto Stop
cable connectors are secure at the sensor and console.
2
Check for 5vDC at the upper PCA or console. Disconnect the Auto Stop
cable connector from the upper PCA or console and measure the
voltage from the console. If 5vDC is not present replace the upper
PCA or console. If 5vDC is present then continue troubleshooting
the Auto Stop cable.
3
Check for 5vDC at the Auto Stop sensor. Disconnect the Auto Stop
cable connector from the Auto Stop sensor, turn the treadmill’s
"On/Off" switch to "On", and check for 5vDC between the red and
black wire in the Auto Stop cable connector. If 5vDC is present at
the at the Auto Stop connector of the console, but not at the end of
the cable, then replace the Auto Stop cable.
Summary of Contents for TRM10/GEN06
Page 2: ......
Page 23: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 21...
Page 93: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 91...
Page 140: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 138...
Page 141: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 139...
Page 142: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 140...
Page 143: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 141...