Figure 19: Hand Held - Chest Strap Heart Rate PCA
Wireless Heart Rate Does Not Work
1
Verify wireless heart rate with a known good chest strap transmitter
or test transmitter. If the heart rate reading is erratic,
incorrect, or absent, continue with step 2.
NOTE: It may be necessary to lean in closer to the console at first to
allow receiver to begin to acquire a heart rate signal.
2
Verify that the HHHR board has the correct operating voltage.
Connect a voltmeter to VCC and Ground on the Power/Signal connector.
The voltage should read between 4.5 and 5.5VDC.
3
Identify other sources of wireless interference signals in close
proximity to the unit (such as Wi-Fi networks, cordless phones,
etc.).
NOTE: Wi-Fi network is transmitting in close proximity to the treadmill
the heart rate system MAY pick it up. Using an ohmmeter, verify that
upper and lower PCAs have a good electrical path to chassis ground.
4
If the above procedures do not correct the problem, replace the
heart rate board.
Possible sources of interference signals include, BUT NOT LIMITED TO:
Wi-Fi Network Routers
Cordless Telephones
Cell Phones
Electronic Dog Fences
Garage Door Remotes
Noisy AC feeds
Florescent light ballasts
Summary of Contents for TRM10/GEN06
Page 2: ......
Page 23: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 21...
Page 93: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 91...
Page 140: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 138...
Page 141: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 139...
Page 142: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 140...
Page 143: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 141...