Bolt equipment to floor

Precor recommends that the strength equipment be bolted down at all anchoring
points. Bolting is made possible through the bolt holes on each foot. The inside
diameter of each hole is 14.3 mm.

NOTE

As floor materials vary, it is important to consult a licensed

contractor to advise on proper bolting techniques and appropriate
fastener types.

Figure 14

CAUTION

Standards can change. Precor recommends you keep apprised of

your local industry standards. Precor shall not be held liable for failure to
properly bolt the strength equipment to the floor.

Apply labels

Figure 15

1. Attach the

Instructional label

to the inside shroud under the top cap. The label should be

aligned with the left and right edge of the tray on the top cap. There are small marks on the
lower lip of the top cap to indicate the proper label position.

Verify operation of equipment

Once assembly is complete, verify safe operation by checking the following points:

l

Cable tension is correct and the cable is moving smoothly on its pulleys.

l

Movement arm is stable and moves smoothly through its range of motion.

l

Adjustment points are stable and move smoothly through their range of motion.

Disassemble the equipment

You may occasionally need to disassemble this unit to move it between rooms or buildings. In such
cases, reverse the assembly steps in this manual to
disassemble. After the unit has been moved, follow the steps in this manual to reassemble it.

WARNING: You will need assistance to disassemble this unit. The weight tower can become
unstable during parts when disassembling. Make sure the weight tower is supported safely
throughout the process and NEVER attempt to disassemble by yourself.

Maintenance information

It is important that the equipment be maintained in accordance with the Vitality Selectorized Line
Maintenance Guide. Visit any Vitality Selectorized product page at

www.precor.com

to view the

guide.

©2021 Precor Incorporated

|

VSL Multi-Press

|

Assembly Guide

|

P/N CWR247777-102 ENU 31 July 2021

|

5

Summary of Contents for Vitality Series

Page 1: ... H175 2 cm idle Figure 1 Begin Assembly CAUTION Do not fully tighten fasteners until instructed to do so The equipment is designed to be freestanding however it can be bolted to the floor for extra stability Precor highly recommends that the equipment be bolted to the floor to reduce the risk of toppling the equipment due to improper use Since floor construction varies please consult a professiona...

Page 2: ...slide twenty three 10 lb 4 5 kg weight plates onto the guide rods one by one 5 Slide the ring at the end of the tether on the weight selection pin over the right hand post on the top weight plate 6 Slide the top weight plate with weight stack stem onto the two guide rods and lower the stem through the center holes of the weight plates Make sure the yellow T handle on the top weight plate faces the...

Page 3: ...le down through the tower frame 4 At the bottom of the weight tower frame thread the cable through the lower pulley Pass the cable from the weight tower to the seat frame assembly and thread it around the horizontal pul ley Note Be sure that the cable retaining brackets do not interfere with the travel of the cable 5 Thread the cable through the lower vertical pulley on the seat frame assembly the...

Page 4: ...nit 3 M10 x 30 mm hex head bolt 3 11 mm flat washer 2 Attach the back pad to the back pad mounting locations on the seat frame using Note The narrow end of the back pad should face upward 1 M10 x 75 mm hex head bolt at the top of the pad 2 M10 x 30 mm hex head bolts at the bottom of the pad 3 11 mm flat washers Install weight stack shroud and top cap The inside shroud has a slot for weight selecti...

Page 5: ...ify safe operation by checking the following points l Cable tension is correct and the cable is moving smoothly on its pulleys l Movement arm is stable and moves smoothly through its range of motion l Adjustment points are stable and move smoothly through their range of motion Disassemble the equipment You may occasionally need to disassemble this unit to move it between rooms or buildings In such...

Reviews: