AFV-P Series High Performance Programmable AC Power Supply
29
The description for the items and the icons at the TESTING subpage (ADVANCED
mode) are given as follows:
1)
: Press to set the operational mode, with two options
of ADVANCE and BASIC.
2)
: Press to set the output mode, with two options of
AC and DC.
3)
: Press to enable/disable the over current foldback,
with two options of OFF and ON.
4)
: Press to set the start angle, with options from 0
to
359
.
5)
: Press to set the end angle, with options from 0
to
359
.
6)
: Press to set the power-on status, with three options
of OFF, ON and LAST.
7)
: Press to set the voltmeter point, with two options of
INT and EXT.
8)
: Press to enable/disable the fail stop feature, with
two options of OFF and ON.
9)
: Press to enable/disable the consecutive step feature,
with two options of ON and OFF.
10)
: Press to enable/disable the synchronized signal,
with three options of EVENT, OFF and ON.
11)
: Press to move to the previous page of the TESTING subpage.
12)
: Press to move to the next page of the TESTING subpage.