background image

5

1.01

 

The COYOTE Closure contains every-

 

thing needed for installation except hand 

tools, vinyl tape, filled cable cleaning fluid, and
C-Cement.

1.02 

Tools Needed:

 

•  1/2" socket*

 

•  7/16" socket* 

 

•  3/8" socket/Can wrench

 

•  Snips

 

•  Ratchet Wrench*

 

•  Torque Wrench (capable of reading 

 

   50 inch lbs.)*

 

•  Fiber optic cable opening tools

*Available from Preformed Line Products 

2.00  DESCRIPTION AND CLOSURE 

CAPACITIES

2.01

 

For Safety Considerations, refer to Section

 

21.00 of this procedure.

2.02

 

The COYOTE Closure series organizes,   

 

distributes and protects all types of fiber 

optic cable with a water and air tight seal.

2.03

 

The COYOTE Closure series accommo-  

 

dates the following splice trays and splice 

connectors (Table 1):

TABLE 1

3.00  END PLATE CONFIGURATIONS 

3.01

 

Two versions of the Three-Section End    

 

Plate are available for the COYOTE Clo-

sure; one which accepts up to six cables, and one 
which accepts up to four larger cables. (Figures 7A 
and 7B)

A = 7/8" (2.22 cm)  
      diameter

B = 3/4" (1.90 cm)
      diameter

FIGURE 7A - DIAGRAM OF SIX PORT 

END PLATE

A = 1" (2.54 cm)         
diameter

B = 1-1/4" (3.18 cm)
      diameter

FIGURE 7B - DIAGRAM OF 

FOUR PORT END PLATE

A

A

B

B

A

A

B

6.0" X 22" (15.24 cm x 55.88 cm) COYOTE Closure

Splice Tray 

Catalog 

Number

Description

Usable 

Connectors

Splice 

Capacity 

Per Tray

Maximum No. 

of Trays Per 

Closure

Maximum 

Closure Splice 

Capacity

80805110 or 

80805514

36 Count 

Single Fiber 

Tray

Single Fusion

36

4

144

Single 

Mechanical

36

4

144

8001127

Low Profile 

Tray

Single Fusion

36

6

216

80805146

96 Count 

Mass 

Ribbon 

Fiber Tray

Mass 

Mechanical*

96

2

192*

Mass Fusion*

144

2

288*

8.5" X 22"(21.59 cm x 55.88 cm) COYOTE Closure 

Splice Tray 

Catalog 

Number

Description

Usable 

Connectors

Splice 

Capacity 

Per Tray

Maximum No. 

of Trays Per 

Closure

Maximum 

Closure Splice 

Capacity

80805110 or 

80805514

36 Count 

Single Fiber 

Tray

Single Fusion

36

8

288

Single 

Mechanical

36

8

288

8001127

Low Profile 

Tray

Single Fusion

36

11

396

80805146

96 Count 

Mass 

Ribbon 

Fiber Tray

Mass 

Mechanical*

96

4

384*

Mass Fusion*

144

4

576*

* Assumes 12 fiber ribbon is utilized. Also holds 16 single count splices.

A

A

B

Summary of Contents for COYOTE 80805112

Page 1: ...LICATION 6 7 5 INTERNAL BOND PROCEDURE 7 6 END PLATE PREPARATION 8 7 END PLATE ASSEMBLY 8 9 8 UNITUBE PREPARATION 10 9 INSTALLING TRANSITION COMPARTMENT FOR SINGLE TUBE CABLE 10 11 10 SECURING UNITUBE...

Page 2: ...LOSURE DIMENSIONS CM 80805258 6 0 x 22 15 24 X 55 88 80805259 8 5 x 22 21 59 X 55 8 1 2 3 4 PLP Catalog Number Splice Tray Splice Capacity 80805110 Single Fiber Tray 36 80805509 Blank Tray 36 80805514...

Page 3: ...Tape not 4 1 2 2 5 6 1 2 2 3 5 6 4 PLP Catalog Number Description 80805105 Three Section Six Port End Plate Kit 80806037 3 4 plugs 2 80806180 7 8 plugs 2 8003371 Future Cable Port Kit for 7 8 port 56...

Page 4: ...t 80805293 Transport Tube Kit 6 per kit 80805107 Strength Member Bracket Kit 2 per kit 80805431 Long Strength Member Bracket Kit 2 per kit 8003280 Transition Tube Kit 8003281 External Bond Clip Kit 2...

Page 5: ...8 2 22 cm diameter B 3 4 1 90 cm diameter FIGURE 7A DIAGRAM OF SIX PORT END PLATE A 1 2 54 cm diameter B 1 1 4 3 18 cm diameter FIGURE 7B DIAGRAM OF FOUR PORT END PLATE A A B B A A B 6 0 X 22 15 24 c...

Page 6: ...eck whether the LOCK TAPE Sealant wrap is the proper diameter to ensure a water and air tight seal Figure 9 For the Six Port End Plate the orange colored end is used to measure cables entering the 7 8...

Page 7: ...check gauge LOCK TAPE Sealant must be reapplied It is acceptable to reapply the original LOCK TAPE Sealant Figure 13 SLOT 4 04 Using the provided Emery Cloth thoroughly scuff the cable sheath for 5 1...

Page 8: ...ree End Plate sections together Remove the packaging plugs 6 02 Refer to Table 2 for the measurement of sheath to extend beyond the inside of the End Plate for the type of cable and bond connector bei...

Page 9: ...insert ports at this time Future cable entry ports will t in only the 7 8 ports of the Six Port End Plate and different future cable entry ports are available for both the 1 ports and the 1 1 4 ports...

Page 10: ...IGURE 21 CORRECT END PLATE ALIGNMENT 7 10 Apply vinyl tape to the remaining 1 4 1 2 64 1 27 cm Paragraph 7 03 of exposed LOCK TAPE Sealant on the cable outside the End Plate 8 00 UNITUBE PREPARATION 8...

Page 11: ...tion compartment 1 2 1 27 cm past the tie down ports in the bottom of the tray Cut the transition tube at this mark and apply Figure 26 FIGURE 26 MEASURING TRANSITION TUBE PLP TIP Install bers in tran...

Page 12: ...m and trays 1 8 of the 8 5 x 22 21 59 cm x 55 88 cm via transport tubes Wrap the continuous loop and the bers not being spliced until all bers are stored in the transi tion compartment For cut cables...

Page 13: ...5 Secure all transport tubes with the felt tape applied to the inside tie down holes in the transition compartment with two of the tie wraps pro vided Figure 31 FIGURE 31 SECURE TRANSPORT TUBES PLP TI...

Page 14: ...plice block see Figure 37B 13 00 SECURING TRANSPORT TUBES AND ROUTING FIBER IN SPLICE TRAYS 13 01 There are six types of splice trays available for the COYOTE Closure The single ber trays are designed...

Page 15: ...tors and sili cone caulk Place Splice Count Label on cover to identify bers spliced On the back of both trays slots are provided to aid in the removal of splice protectors or connectors Figure 39 FIGU...

Page 16: ...he hinges on the splice tray and snap into place Figure 42 FIGURE 42 REPLACE SPLICE TRAY COVER 13 06 When routing the ber in the MASS FIBER SPLICE TRAY for MASS MECHANICAL route bers 1 1 2 times aroun...

Page 17: ...6B to the torque bar bracket on the bottom of the End Plates with the bolts provided Make sure the side of the torque bar labelled 3 Section End is nearest the Three section End Plate The torque bars...

Page 18: ...47A PLP TIP If the hold down strap is snug against the studs lift the tab using a screwdriver as demon strated in Figure 47B FIGURE 47A REMOVE SPLICE TRAY HOLD DOWN STRAP FIGURE 47B HOLD DOWN STRAP RE...

Page 19: ...branch cable is being spliced More room in the storage compartment is required for the storage of slack buffer tube 14 06 Follow Paragraph 4 01 for cable opening measurements 14 07 Separate the buffe...

Page 20: ...Plate 16 04 Remove one hex nut from each of the ground studs 16 05 Apply the Exterior Bond Braid and re apply hex nuts and tighten When reattaching hex nuts secure using a can wrench or torque wrench...

Page 21: ...le racking or hand hole racking 18 02 Remove one hex nut from each of the two upper ground inserts 17 00 STRAND MOUNT PROCEDURE 17 01 The Adjustable Aerial Hanger Bracket Catalog 8003325 can be used f...

Page 22: ...the Ts on top of the Manhole Support Brackets until the support bar is centered over the COYOTE Closure PLP TIP Cable tie the support bar to the rack steps for added security 19 00 BURIED INSTALLATIO...

Page 23: ...23...

Page 24: ...24 SP2822 5 P O Box 91129 Cleveland Ohio 44101 440 461 5200 www preformed com email inquiries preformed com...

Reviews: