background image

6

3.02

 

See Figure 8 for hardware that can be used  

 

with the Three-Section End Plate.

4.00  CABLE PREPARATION–LOCK-

TAPE SEALANT APPLICATION

NOTE: 

For OPGW application, see procedure en-

titled, “OPGW Cable and End Plate Preparation 
for COYOTE

®

 Closure” (SP2849). 

4.01

 

Cable sheath opening measurements, for  

 

both size closures, whether using unitube or 

buffer tube, are 152" (386.10 cm) for continuous 
loop/express applications, and 76" (193.04 cm) 
for cut cable.

NOTE:

  The COYOTE Closure is designed for main 

cables to enter the bottom outside cable ports 
and for branch cables to enter the bottom middle 
and upper cable ports in the End Plate. 

PLP TIP:

  Where irregular cable ends exist, measure 

from the shortest cable to establish End Plate 
location.

4.02

 

The color-coded COYOTE Cable Measure 

 

Tapes are used to determine the number of 

half-lapped layers of LOCK-TAPE Sealant required 
to seal the cable in the End Plate. The back of the 
Measure

 

Tape is used to check whether the LOCK-

TAPE Sealant wrap is the proper diameter to ensure 
a water and air tight seal. (Figure 9) 

For the Six Port End Plate, the orange-colored end is 
used to measure cables entering the 7/8" (2.22 cm) 

FIGURE 8 - END PLATE HARDWARE

diameter ports while the blue-colored end measures 
cables entering the 3/4" (1.90 cm) diameter ports.

For the Four Port End Plate, the COYOTE Cable 
Measure Tape has a green-colored end for the 1" 
diameter port and a red-colored end for the 1-1/4" 
diameter port. 

FIGURE 9 - COYOTE CABLE MEASURE

 

 TAPE 

(TAPE FOR SIX PORT END PLATE SHOWN)

4.03

 

TO USE COYOTE CABLE MEASURE    

 

TAPE:

 

•  Wrap the 

correct end

 of COYOTE Cable 

Measure Tape around cable where it will 
enter the End Plate.

 

•  If the index line falls directly between two 

numbers use the higher number. 

 

•  The number on the COYOTE Cable Mea-

sure Tape indicates the number of half-
lapped layers of LOCK-TAPE Sealant to be 
applied around the cable. (Figure 10)

FIGURE 10 - MEASURING CABLE --

BE SURE TO USE CORRECT END OF CABLE 

MEASURE TAPE

"L" BRACKET

BOLT
HEAD-
TOP

BOLT-
BOTTOM

INTERNAL 
GROUND
INSERTS
FOR EACH
PORT

STRENGTH
MEMBER
CAP

TORQUE BAR 
BRACKET

BLUE

BLUE

ORANGE

ORANGE

Summary of Contents for COYOTE 80805112

Page 1: ...LICATION 6 7 5 INTERNAL BOND PROCEDURE 7 6 END PLATE PREPARATION 8 7 END PLATE ASSEMBLY 8 9 8 UNITUBE PREPARATION 10 9 INSTALLING TRANSITION COMPARTMENT FOR SINGLE TUBE CABLE 10 11 10 SECURING UNITUBE...

Page 2: ...LOSURE DIMENSIONS CM 80805258 6 0 x 22 15 24 X 55 88 80805259 8 5 x 22 21 59 X 55 8 1 2 3 4 PLP Catalog Number Splice Tray Splice Capacity 80805110 Single Fiber Tray 36 80805509 Blank Tray 36 80805514...

Page 3: ...Tape not 4 1 2 2 5 6 1 2 2 3 5 6 4 PLP Catalog Number Description 80805105 Three Section Six Port End Plate Kit 80806037 3 4 plugs 2 80806180 7 8 plugs 2 8003371 Future Cable Port Kit for 7 8 port 56...

Page 4: ...t 80805293 Transport Tube Kit 6 per kit 80805107 Strength Member Bracket Kit 2 per kit 80805431 Long Strength Member Bracket Kit 2 per kit 8003280 Transition Tube Kit 8003281 External Bond Clip Kit 2...

Page 5: ...8 2 22 cm diameter B 3 4 1 90 cm diameter FIGURE 7A DIAGRAM OF SIX PORT END PLATE A 1 2 54 cm diameter B 1 1 4 3 18 cm diameter FIGURE 7B DIAGRAM OF FOUR PORT END PLATE A A B B A A B 6 0 X 22 15 24 c...

Page 6: ...eck whether the LOCK TAPE Sealant wrap is the proper diameter to ensure a water and air tight seal Figure 9 For the Six Port End Plate the orange colored end is used to measure cables entering the 7 8...

Page 7: ...check gauge LOCK TAPE Sealant must be reapplied It is acceptable to reapply the original LOCK TAPE Sealant Figure 13 SLOT 4 04 Using the provided Emery Cloth thoroughly scuff the cable sheath for 5 1...

Page 8: ...ree End Plate sections together Remove the packaging plugs 6 02 Refer to Table 2 for the measurement of sheath to extend beyond the inside of the End Plate for the type of cable and bond connector bei...

Page 9: ...insert ports at this time Future cable entry ports will t in only the 7 8 ports of the Six Port End Plate and different future cable entry ports are available for both the 1 ports and the 1 1 4 ports...

Page 10: ...IGURE 21 CORRECT END PLATE ALIGNMENT 7 10 Apply vinyl tape to the remaining 1 4 1 2 64 1 27 cm Paragraph 7 03 of exposed LOCK TAPE Sealant on the cable outside the End Plate 8 00 UNITUBE PREPARATION 8...

Page 11: ...tion compartment 1 2 1 27 cm past the tie down ports in the bottom of the tray Cut the transition tube at this mark and apply Figure 26 FIGURE 26 MEASURING TRANSITION TUBE PLP TIP Install bers in tran...

Page 12: ...m and trays 1 8 of the 8 5 x 22 21 59 cm x 55 88 cm via transport tubes Wrap the continuous loop and the bers not being spliced until all bers are stored in the transi tion compartment For cut cables...

Page 13: ...5 Secure all transport tubes with the felt tape applied to the inside tie down holes in the transition compartment with two of the tie wraps pro vided Figure 31 FIGURE 31 SECURE TRANSPORT TUBES PLP TI...

Page 14: ...plice block see Figure 37B 13 00 SECURING TRANSPORT TUBES AND ROUTING FIBER IN SPLICE TRAYS 13 01 There are six types of splice trays available for the COYOTE Closure The single ber trays are designed...

Page 15: ...tors and sili cone caulk Place Splice Count Label on cover to identify bers spliced On the back of both trays slots are provided to aid in the removal of splice protectors or connectors Figure 39 FIGU...

Page 16: ...he hinges on the splice tray and snap into place Figure 42 FIGURE 42 REPLACE SPLICE TRAY COVER 13 06 When routing the ber in the MASS FIBER SPLICE TRAY for MASS MECHANICAL route bers 1 1 2 times aroun...

Page 17: ...6B to the torque bar bracket on the bottom of the End Plates with the bolts provided Make sure the side of the torque bar labelled 3 Section End is nearest the Three section End Plate The torque bars...

Page 18: ...47A PLP TIP If the hold down strap is snug against the studs lift the tab using a screwdriver as demon strated in Figure 47B FIGURE 47A REMOVE SPLICE TRAY HOLD DOWN STRAP FIGURE 47B HOLD DOWN STRAP RE...

Page 19: ...branch cable is being spliced More room in the storage compartment is required for the storage of slack buffer tube 14 06 Follow Paragraph 4 01 for cable opening measurements 14 07 Separate the buffe...

Page 20: ...Plate 16 04 Remove one hex nut from each of the ground studs 16 05 Apply the Exterior Bond Braid and re apply hex nuts and tighten When reattaching hex nuts secure using a can wrench or torque wrench...

Page 21: ...le racking or hand hole racking 18 02 Remove one hex nut from each of the two upper ground inserts 17 00 STRAND MOUNT PROCEDURE 17 01 The Adjustable Aerial Hanger Bracket Catalog 8003325 can be used f...

Page 22: ...the Ts on top of the Manhole Support Brackets until the support bar is centered over the COYOTE Closure PLP TIP Cable tie the support bar to the rack steps for added security 19 00 BURIED INSTALLATIO...

Page 23: ...23...

Page 24: ...24 SP2822 5 P O Box 91129 Cleveland Ohio 44101 440 461 5200 www preformed com email inquiries preformed com...

Reviews: