Assembly Instructions, POWER RAIL
TM
‒ Two-Tier Tilt Kit
3
Spacing Calculations (16 Inch on Center Joists)
Module
Type
Angle, ϴ
(degrees)
Tilt Leg
Length,
H (in.)
Span
Length,
X (in.)
Cantilever
Length,
C (in.)
Foot
Spacing,
Y (in.)
Strongback
Length,
(in.)
60 Cell
15
23.3
84
42
80
126
25
37.2
84
42
80
35
51
84
42
80
45
64.4
84
42
80
72 Cell
15
26.4
100
50
96
150
25
42.6
100
50
96
35
58.5
100
50
96
45
74
100
50
96