User Guide
EH1230
needs to be replaced,
proceed as follows:
•
Connect the brown wire to the terminal labelled
"L".
•
Connect the blue wire to the terminal labelled
"N".
•
Connect the green/yellow wire to the terminal
labelled with the earth symbol or "E".
•
Make sure that the cord-grip is positioned
correctly (over the outer sheath of the cable) and
it fully tightened.
Fuse
(5A)
Earth
(Green
Yellow)
Neutral
(Blue)
Live
(Brown)
PAT TESTING.
When used in a workplace, this product must be safety-tested
yearly by a qualified electrician (PAT Tested) in order to comply
with the Electricity at Work Regulations.
We recommend that it is PAT tested regularly when used in a
domestic environment.
GENERAL SAFETY REQUIREMENTS
Domestic wiring must be tested periodically by a qualified
electrician at least once every 10 years or at every change of
occupancy.
For office and retail premises, and buildings such as village halls,
the wiring must be inspected at least once every 5 years.
It is recommended that all building be fitted with smoke alarms (it is
mandatory for new buildings).
STORAGE
Before putting the unit into storage remove the bung from the
water drain; then operate the unit for half a day in "fan only" mode.
Switch off the unit, and disconnect from the mains supply, wrap the
cable neatly, place the unit in a plastic bag and store in a dry place
until next required.
Page 10