Installation Instructions
Visit the Premier Mounts website at www.mounts.com
Page 9
GB-AVSTOR5
W
Ceiling
Framework
Quick Lock
➋
Adjust the
1
/
16
˝
braided cable so that the cable forms a
15
° angle away from the corner of the ceiling box
.
When adjusting the tension of the weight-bearing
side of the Quick Lock, the
1
/
16
˝ braided
cable must
be pulled through the Quick Lock until the desired
tension is attained. Do not overtighten.
➌
When you have the desired tension, pull the
1
/
16
˝
braided cable through the other side of the Quick
Lock.
Once the tension has been adjusted, be sure that
there is a minimum of 6” of excess
1
/
16
˝
braided cable
on the non-weight bearing side of the Quick Lock.
➍
Use cable cutters to remove any remaining
1
/
16
˝
braided cable (optional).
Go to
Wiring the Electrical Box
on page 10.
6” Excess
1
/
16
˝ Braided Cable
1
/
16
˝ Braided
Cable To Ceiling
Attachment
Step 2
It is recommended that the following steps be
performed by two people.
➊
Lower the ceiling box into the exposed ceiling
framework.
Make sure the ceiling box is seated completely in
the ceiling framework before releasing it.
15°