background image

1

INSTALLATION INSTRUCTIONS

IMPORTANT

Before assembling your PREMISE LED
fixture, please make sure that you 

carefully read through this 

instruction sheet. Consider having 

your fixture installed by a qualified 
licensed electrician.

Note

: The important safeguards and 

instructions that appear in this sheet 

are not meant to cover all possible 
conditions and situations that may 

occur. It must be understood that 
common sense, caution, and care 

are factors that cannot be built into 

any product. These factors must be 
supplied by the person(s) caring for 

and operating the fixture. 

VP2 SERIES

VAPOR PROOF FIXTURE

For use with:

WHAT’S IN THE BOX

LED Fixture

2 x 1/2" Cable Glands

2 x Mounting Clips

4 x Mounting Screws

4 x Screw Anchors

1 x 1/2" Knockout Plugs

5 x Wire Nuts

WHAT YOU’LL NEED

Safety Glasses

Wire Cutters

Wiring Supplies as specified by Code

PREMISE LED Inc.

80-86 Carrier Drive

Toronto, ON Canada

M9W 5R1

PREMISELED.COM

Turn off electrical power at fuse or circuit breaker box 

before wiring fixture to the power supply.

Turn off the power when you perform any 

maintenance.

Verify that supply voltage is correct by comparing it 

with the luminaire label information.

Keep lens tightly closed when in operation.

Modifications to the product voids the warranty.

WARNING

Model #

Voltage

Wattage

CCT

VP2-4324-3

120-347V

32W

4000K

VP2-4325-3

120-347V

32W

5000K

VP2-4464-3

120-347V

46W

4000K

VP2-4465-3

120-347V

46W

5000K

VP2-8654-3

120-347V

65W

4000K

VP2-8655-3

120-347V

65W

5000K

Summary of Contents for VP2 Series

Page 1: ... LED Fixture 2 x 1 2 Cable Glands 2 x Mounting Clips 4 x Mounting Screws 4 x Screw Anchors 1 x 1 2 Knockout Plugs 5 x Wire Nuts WHAT YOU LL NEED Safety Glasses Wire Cutters Wiring Supplies as specified by Code PREMISE LED Inc 80 86 Carrier Drive Toronto ON Canada M9W 5R1 PREMISELED COM Turn off electrical power at fuse or circuit breaker box before wiring fixture to the power supply Turn off the po...

Page 2: ... gland located at the end of the fixture Insert your flexible power cable not included through the cable gland allowing for sufficient length of stripped cable inside the housing to make connections and tighten the gland 5 Connect the GROUND connection to the supplied green grounding conductor 6 Unplug the ballast disconnect Make connections to the ballast disconnect leads while always observing t...

Page 3: ...SAIRES LUNETTES DE PROTECTION PINCE COUPE FILS FOURNITURES DE CÂBLAGE ÉLECTRIQUE TELLES QUE SPÉCIFIÉES PAR LE CODE ÉLECTRIQUE PREMISE LED Inc 80 86 Promenade Carrier Toronto ONTARIO Canada M9W 5R1 PREMISELED COM Toujours débrancher au boîtier de fusibles ou de disjoncteurs avant de câbler le luminaire à l alimentation électrique Toujours éteindre le courant avant d effectuer un entretien Vérifier ...

Page 4: ... Insérer le câble d alimentation flexible à travers le presse etoupe en gardant une longeur suffisante de câble dénudé à l intérieur du boîter et serrer le presse étoupe 4 Raccorder le fil vert à la mise à la terre 5 Debrancher le connecteur Raccorder les fils d alimentation aux fils du connecteur en respectant les polarités soit le NOIR pour le VIVANT et le BLANC pour le NEUTRE Rebrancher le conn...

Reviews: