background image

SWIM SPAS OWNER’S MANUAL 

MODELS: SWIMMER’S EDGE 18, DUAL ZONE 18, 

SWIMMER 18, SWIMMER 14 

Premium Leisure, LLC 

6101 45

th

 St. N. 

St. Petersburg, FL 33714 

727.573.9611 

www.PremiumLeisure.com

Part Number 7068 

Revised 03/10 

Summary of Contents for Dual Zone 18

Page 1: ...SPAS OWNER S MANUAL MODELS SWIMMER S EDGE 18 DUAL ZONE 18 SWIMMER 18 SWIMMER 14 Premium Leisure LLC 6101 45th St N St Petersburg FL 33714 727 573 9611 www PremiumLeisure com Part Number 7068 Revised 0...

Page 2: ...Company __________________________ Address __________________________ Telephone __________________________ Swim Spa Date Delivered __________________________ Model __________________________ Color __...

Page 3: ...the limited warranty card within 30 days of purchase or register online at http premiumleisure com owners shtml to ensure you understand what you are entitled to in terms of service If you have any qu...

Page 4: ...b site at www PremiumLeisure com or call our customer care center at 727 573 9611 WARNING This manual was written to ensure the proper use and installation of your swim spa Any modifications to the pr...

Page 5: ...ach spa use Dangers RISK OF ACCIDENTAL DROWNING Extreme caution must be exercised to prevent unauthorized access by children To avoid accidents ensure that children cannot use this spa unless they are...

Page 6: ...should consult a physician before using a spa swim spa since some medication may include drowsiness while other medication may affect heart rate blood pressure and circulation Do not connect auxiliary...

Page 7: ...4 F 40 C Water temperatures between 100 F 38 C and 104 F 40 C are considered safe for a healthy adult Lower water temperatures are recommended for young children senior citizens persons with sensitivi...

Page 8: ...ground fault circuit interrupter GFCI breaker prior to using your swim spa each time to ensure it operates properly Any electrical devices near your swim spa must be GFCI protected and out of reach f...

Page 9: ...on of poured concrete footings extending below the frost line beneath the pad to prevent the possibility of future shifting 5 For internal installations check the load carrying capabilities of the flo...

Page 10: ...and or turbine and all equipment from the weather by ensuring the cabinet panels are secure at all times 10 Allow 36 inches 1 meter of unobstructed access to all sides of your swim spa for normal ser...

Page 11: ...e covered under your warranty All swim spas must be over current protected with a built in GFCI or RCD in the service panel Model Spa side Swim side Volts Freq Amps GFCI RCD Wire size Controller Panel...

Page 12: ......

Page 13: ...Figure 5 Electrical Service for all models Swimmer s Edge 18 Dual Zone 18 Swimmer 18 and Swimmer 14 Single phase 240V domestic version See wire size chart on page 9 Page 11 For HELP call 727 573 9611...

Page 14: ...ll models Swimmer s Edge 18 Dual Zone 18 Swimmer 18 and Swimmer 14 Single Service 1x32A export version All wiring is 3x4 mm2 solid copper See wire size chart on page 9 Note DIP switch A2 MUST BE OFF P...

Page 15: ...l Service Dual Service 2x16A for Dual Zone 18 Swimmer 18 and Swimmer 14 export models All wiring is 5x1 5 mm 2 solid copper See wire size chart on page 9 Note DIP switch A2 MUST BE ON Page 13 For HELP...

Page 16: ...l Service Three Phase 3x16A for Dual Zone 18 Swimmer 18 and Swimmer 14 export models All wiring is 5x1 5 mm 2 solid copper See wire size chart on page 9 Note DIP switch A2 MUST BE ON Page 14 For HELP...

Page 17: ...U S Can Wiring Dual Zone 18 Swimmers 14 18 Swim Side Figure 9 Wiring Diagram for Dual Zone 18 Swimmer 18 and Swimmer 14 models with PEL2KM3 Control Pack Swim Side Page 15 For HELP call 727 573 9611...

Page 18: ...Page 16 For HELP call 727 573 9611...

Page 19: ...wimmer 14 18 Swim Side Figure 10 Wiring Diagram for Dual Zone 18 Swimmer 18 and Swimmer 14 models with HSEX2000 Control Pack Swim Side See wire size chart on page 9 Page 17 For HELP call 727 573 9611...

Page 20: ...Figure 11 Board Diagram for Dual Zone 18 Swimmer 18 and Swimmer 14 models Export 220 240V version with HSEX2000 Control Pack Page 18 For HELP call 727 573 9611...

Page 21: ...U S and Canada Wiring All Models Spa Side Page 19 For HELP call 727 573 9611...

Page 22: ...Figure 13 Board Diagram for all models Single phase 240V Domestic version Page 20 For HELP call 727 573 9611...

Page 23: ...Wiring Dual Zone 18 Swimmer 14 18 Spa Side Figure 14 Export Wiring Diagram for Dual Zone 18 Swimmer 18 and Swimmer 14 for GS510SZ Control Pack See wire size chart on Pg 9 Page 21 For HELP call 727 57...

Page 24: ...15 Board Diagram for all models Export version for GS510SZ Control Pack Page 22 For HELP call 727 573 9611 Figure 16 Panel Button Positions for Dual Zone 18 Swimmer 18 and Swimmer 14 Models Export ve...

Page 25: ...ep in its entirety before proceeding Caution Running the swim spa pump dry without water running through it can cause IMMEDIATE damage and will void the warranty Be sure that the swim spa is installed...

Page 26: ...not be covered under warranty Figure 19 Unions Tight 6 Check that the unions on all pumps are tight 7 Clean out any foreign debris from within the service access area or inside of the swim spa itself...

Page 27: ...r pressure is used foaming water can force air into the pipes and cause startup problems Important To assure that the pump is properly primed fill the swim spa through the filter area only 6 Fill the...

Page 28: ...minum tank next to the fill cap If your system is low on oil the LED digital readout will indicate LOW OIL You must turn the system off at the breaker and wait 5 minutes before turning it back on This...

Page 29: ...r every 6 12 months uipment 3 Attached a garden hose to the valve open the valve and drain Note For faster draining you may use a sump pump or siphon 1 Turn off the breaker and disconnect electrical p...

Page 30: ...ts and you should see an increase in jet pres the water and airflow of every river jet if necessary An air mixture intensifies the level of your current Turn the air control val counterclockwise to in...

Page 31: ...ill help to prime Do this only 4 times 5 If the water is running smoothly through the lines open the air control valve to the jets and you should see an increase in jet pressure Check and adjust the w...

Page 32: ...ng capacity making the pH difficult to change 2 pH 7 2 7 8 Use Spa Up to raise the pH level and Spa Down to lower it Caution A pH lower than 7 2 can harm the metal surfaces of your swim spa and irrita...

Page 33: ...ast two minutes To display the set temperature press the WARM or COOL button once To change the set temperature press the WARM or COOL button a second time before the LCD stops flashing Each press of...

Page 34: ...n temperature is current Sleep Mode heats the swim spa to within 20 F 10 C of the set temperature only during filter cycles SL will display solid when temperature is not current and will alternate wit...

Page 35: ...is set at 100 F 37 C The last measured temperature is constantly displayed on the LCD and is current only when the pump has been running for at least two minutes To display the set temperature press...

Page 36: ...by first pressing the WARM or COLD button then pressing the MODE button Standard Mode is programmed to constantly maintain the desired temperature Std will be displayed momentarily when you switch in...

Page 37: ...after it detects the swim spa temperature has risen to 45 F 7 2 C Programming Summary Figure 24 VL600S Programming Summary NOTE FOR ALL DOMESTIC SWIM SIDE MVP 260 TOPSIDE CONTROLS Follow the above ste...

Page 38: ...s used to switch between standard economy and sleep modes Press Mode To enter mode programming press Cool through to desired mode LCD flashes until confirmed then press Mode to confirm selection Stand...

Page 39: ...s off after 15 minutes Light Button If Equipped Press the Light button to turn the spa light system on and off The LED light system is preprogrammed with an assortment of lighting effects When you tur...

Page 40: ...heats the spa water to within 20 F 11 C of set temperature only during filter cycles Filter Cycle Programming Optional As explained above in a 24 hour circulation pump system the filtration cycle pro...

Page 41: ...ts similarly except with the temperature thresholds determined by the switch and without a four 4 minute delay in turnoff See your dealer for details Locking the Panel Press Time Jets 1 then Warm Arro...

Page 42: ...he speed of the unit by pressing the SLOW arrow down button The digital readout numbers range from 50 999 They do not represent anything specific but rather they provide each swimmer a benchmark to en...

Page 43: ......

Page 44: ...astic cover down to protect from water splashing Do not attempt to handle your MP3 player while swimming in your swim spa C o v e r Place the insulated cover on your swim spa Keeping the cover in plac...

Page 45: ...device Figure 30 Swim Spa Cover Sections for 18 Models F r e q u e n t l y A s k e d Q u e s t i o n s Who do I call for warranty information or service Call our customer care center between 8 a m and...

Page 46: ...an my swim spa Use non sudsing cleaners and non oily polishes see page 50 Our Citra Bright Spray Cleaner and our Tub Rub cleaning pad quickly removes scum lines and helps restore your shell s original...

Page 47: ...For HELP call 727 573 9611 PROBLEM CAUSE SOLUTION Breaker trips Wiring error Load Neutral wire not connected to GFCI connected to Neutral bus Wrong GFCI GFCI breaker is wrong size Ozonator wet Remove...

Page 48: ...Thermostat is set too low Check and reset to desired temperature Air open Close air control valve Dirty filter Check and clean filter Blown fuse Check and replace fuse Slide valve closed Check and ope...

Page 49: ...t service HFL HL A substantial difference between sensors was detected possible flow problem Check water level in swim spa and add water if necessary Be sure that slide valves are open Make sure the p...

Page 50: ...n the following maintenance procedures must be followed periodically Cabinets Your cabinet is made from a polymer that combines the durability of plastic with the beauty of simulated wood To clean the...

Page 51: ......

Page 52: ...on level is influenced by two factors 1 Filter Cycle filtration time 2 How much you use your swim spa each week If your water chemistry and water clarity are all proper and your sanitation level is st...

Page 53: ...r cover with clean warm water Foamy water Foam typically results from soap residue on your skin and hair or laundry detergent residue on clothing Take a soapless shower and rinse all clothing in warm...

Page 54: ...MER S EDGE 18 MODEL 2030 Specifications are subject to change without notice For export overseas part numbers please call 727 573 9611 For export overseas electrical rating see the chart on page 9 Pag...

Page 55: ...s 18 Capacity 2 400 USG 9 085 L Dry Weight 2 750 Lbs 1 247 Kg Filled Weight 22 778 Lbs 10 332 Kg Electrical 240VAC 40A 60Hz Swim Side 240VAC 32A 60Hz Spa Side GFCI 50A Swim Side and 40A Spa Side Figur...

Page 56: ...DEL 2022 Specifications are subject to change without notice For export overseas part numbers please call 727 573 9611 For export overseas electrical rating see the chart on page 9 Page 54 For HELP ca...

Page 57: ...er Jets 42 Capacity 2 100 USG 7 949 L Dry Weight 1 900 Lbs 862 Kg Filled Weight 19 424 Lbs 8 811 Kg Electrical 240VAC 48A 60Hz Swim Side 240VAC 32A 60Hz Spa Side GFCI 60A Swim Side 40A Spa Side Figure...

Page 58: ...el 2028 Specifications are subject to change without notice For export overseas part numbers please call 727 573 9611 For export overseas electrical rating see the chart on page 9 Page 56 For HELP cal...

Page 59: ...ter Jets 21 Capacity 2 400 USG 9 085 L Dry Weight 1 900 Lbs 862 Kg Filled Weight 19 424 Lbs 8 811 Kg Electrical 240VAC 48A 60Hz Swim Side 240VAC 32A 60Hz Spa Side GFCI 60A Swim Side 40A Spa Side Figur...

Page 60: ...el 2021 Specifications are subject to change without notice For export overseas part numbers please call 727 573 9611 For export overseas electrical rating see the chart on page 9 Page 58 For HELP cal...

Page 61: ...s 28 With Lounge 29 Without Lounge Capacity 1 600 USG 6 057 L Dry Weight 1 605 Lbs 728 Kg Filled Weight 14 958 Lbs 6 785 Kg Electrical 240VAC 48A 60Hz Swim Side 240VAC 32A 60Hz Spa Side GFCI 60A Swim...

Page 62: ...ible for expenses including removal shipping and re installation of the existing or replacement hot tub The replacement swim spa or part will carry the balance of the original swim spa s warranty if a...

Page 63: ...6101 45th St N St Petersburg FL 33714 727 573 9611 www PremiumLeisure com...

Reviews: