Electrical Specifications
Important –
Qualified and licensed electricians must perform all electrical
hookups. The following specifications must be followed in order to ensure proper
performance and safety.
WARNING:
Starting an incorrectly wired swim spa could cause severe
damage to the mechanical equipment or even bodily harm. Have
your licensed electrician verify GFCI (or RCD) wiring with the
diagrams on pages 10-15 prior to starting the swim spa or call
the technical support line at 727.573.9611.
Caution:
Failure to abide by specifications listed may result in damage to the
equipment and will void the warranty. All swim spas must be wired
with the appropriately sized wiring. Failure to do so will cause
equipment damage and will not be covered under your warranty.
All swim spas must be over current protected with a built-in GFCI (or RCD) in the
service panel.
Model
Spa
side
Swim
side
Volts/Freq. Amps GFCI/
RCD
Wire
size
Controller
/ Panel
All
All
N/A
240/120/60 32 40 3
Wire
#8+Grd
VS500Z/
MVP260
DualZone 18
Swimmer 14
Swimmer 18
N/A
DZ18
Swim14
Swim 18
240/120/60
48
60 3
Wire
#6+Grd
PEL2KM3
ML700
Swimmer’s
Edge 18
N/A
SE 18
240/120/60
40
50
3 Wire
#6+Grd
Power unit
1244/Rem
ote panel
All
(Export)
All
N/A
220-240/50
1x32,
2x16
IEE
WIRE
REG
3x4mm²
5x1.5
mm
2
GS510SZ/
VL600S
DualZone 18
Swimmer 14
Swimmer 18
(Export)
N/A
DZ18
Swim14
Swim 18
220-240/50
1x32,
2x16,
3x16
IEE
WIRE
REG
3x4mm²
5x1.5
mm
2
HSEX2000
/
ML700
Swimmer’s
Edge 18
(Export)
N/A
SE 18
220-240/50
1x32
IEE
WIRE
REG
3x4mm²
Power unit
1245/Rem
ote panel
Table 1 – Domestic/Export (in Gray) Electrical Specification Chart
Page 9
For HELP, call 727.573.9611
NOTE:
The swim side and the spa side will need to be wired independently.