Low-level Settings: XP1 and XP2
The spa pack – located inside the hot tub below the topside control panel – has a
service panel used to set low-level programming options. During troubleshooting,
you may need to check or reset these settings.
Resetting the Spa Pack
To reset the spa pack, press the Select button twice.
Resetting the Low-Level and Breaker Setting
To reset the low-level setting (LL), press
and hold down the Select button for 5
seconds. Use the Change button to set LL
even if it is the present value
. Press
Select to save (breaker settings appear
next).
Model
XP1
XP2
LL
01
02
After setting LL, the breaker current setting
(Br) appears. Press the Change button to
select the appropriate value for your
configuration and then press Select to
save.
For export spas, press the change button
to select the number of phases. (Be sure
the copper jumper configuration on the
power terminal matches the phase
number.)
Configuration
240V 60Hz
240V 50Hz 1
240V 50Hz 2
240V 50Hz 3
Br
48
32(16)
16
16
Ph
-
1
2
3
Figure 36 - Spa Pack
Callouts
Page 53
For HELP, call 727.573.9611
Summary of Contents for Sterling Leisure
Page 39: ...Page 39 For HELP call 727 573 9611...
Page 40: ...Page 40 For HELP call 727 573 9611...
Page 52: ...Page 52 For HELP call 727 573 9611 Figure 35 Functional Diagram for XP1 and XP2...
Page 67: ...Passion Callouts Passion Parts Page 67 For HELP call 727 573 9611...
Page 69: ...Essence Callouts Essence Parts Page 69 For HELP call 727 573 9611...
Page 71: ...Desire Callouts Desire Parts Page 71 For HELP call 727 573 9611...
Page 73: ...Pure Callouts Pure Parts Page 73 For HELP call 727 573 9611...
Page 75: ...Pristine Callouts Pristine Parts Page 75 For HELP call 727 573 9611...