Dry it after cleaning.

Use light soapy water when cleaning the door seal, apply a little talcum powder on it after

natural drying to extend its service life.

Use a soft cloth with water or a little detergent to clean the external surface. Note, keep the

power supply, electric cable and plug away from water to avoid electric shock.

Except on common failures, those who are not service technician should not take apart

and

repair

the freezer on their own, to avoid worsening the trouble. Unauthorized repair of

electrical parts such as compressor or temperature controller is forbidden.

Defrosting

Defrost for better freezing efficiency when the frost film in the cabinet is 4-5mm thick.

When defrosting, turn off the power, take out the frozen foods, open the door for warming

and melting. Use soft cloth to absorb water and clean it up.

Do not use sharp metal tools such as steel brush to clean the frost film when defrosting to

avoid evaporator damage

Troubleshooting

Breakdown

Case

Removal method

The indicator is not on.
The compressor does not start.

The plug is not
connected to the socket.

Plug it.

No power

Connect the socket with power.

The indicator is on, but the compressor
does not work and only buzzes

The power voltage is

98V.

Put a power-regulator with more
than 1000W power together.

The compressor stops a minute after
starting, and restarts after a few minutes,
and so repeatedly.

The power voltage is

132V.

The compressor works normally, but the
temperature in the cabinet lowers too
slowly.

The door is opened too
frequently.

Reduce opening times.

There is too much food in
the cabinet and it is
placed improperly.

Place foods properly and keep
space between them for cold air
ventilation.

The frost film is too thick.

Take out foods and defrost.

The surface of the
condenser is too dirty.

Stop and clean the condenser.

The door does not seal.

Adjust the door seal.

The noise is too loud

The freezer is not placed
on an even surface.

Place it on an even surface.

The fixing of the freezer
is loose.

Tighten the fixing.

There is contact between
pipes.

Separate them.