DISASSEMBLY COMMON PARTS OF FREEZER
Checking the compressor
After the compressor is powered on separately, the compressor does not start and exhaust.
Use a multi-meter to test the resistance between C & M, C&S and S&M :
Normal range of C&M : About 9.36~11.44Ω
Normal range of C&S : About7.02~8.58Ω
Normal range of S&M : About 16.38~20.02Ω
If the test result is not in this range then it means the inner coil has some problem and the compressor cannot work
properly.
Page 13