A - ELECTrIC CONNECTION
PArK 24V code BC07061
B -
sW1 - MICrOsWITHCEs fOr THE GEArCAsE sETTING
DIP 1 - MOTOr DECELErATION CALIBrATION (ON) (POINT C)
DIP 2 - PrOGrAMMING TIMEs (ON)
OPErATING MICrOsWITCH
DIP 3
- Waiting time before the automatic closing (on) (max 5 min.)
DIP 4
- Step by step radio receiver (oFF) - automatic (on)
DIP 5
- Single impulse control (K BUtt)
step by step (oFF) - automatic (on)
DIP 6
- normal working (oFF) – Park working (on)
DIP 7
- encoder exclusion as security (oFF - encoder on / on -
encoder off)
DIP 8
- Function of the key oPenInG 2 check in Park mode.
on - the key oPenInG 2 is always authorized,
oFF- the key oPenInG 2 is authorized only if there is no presence on
InParK.
DIP 9
- Working after black-out
WITH batteries.
on - the rod opens and stops in the opening position with the exclusion
of all controls. When the network input is back, the bar closes
resetting all controls
oFF - the bar carries out the normal working until the battery is
exhausted.
DIP 10
- Working after black-out
WITHOUT batteries.
on - the bar closes
oFF - the bar stops in the point where the black-out happened.
s1
PrOG.
Key for the programming.
TErMINAL BOArD J1
sEC.TrANsf.
Connection for secondary transformer (carried out in the
factory).
CONNECTOr J2
MOTOr
Connection Motor and enCoDer (carried out in the factory).
TErMINAL BOArD J3
1
Central aerial wire connection
2
aerial cable electric shielding connection
3
Common contacts
4
Photoelectric cells contact (nC)
5
Stop button contact (nC)
6
opening 1 button contact (na)
7
Closing button contact (na)
8
Single impulse contact (na)
9
Positive for fixtures input (+24vdc)
10
negative for fixtures input (-24vdc)
11
Battery state connection led (12vdc)
12
Sounding signaller connection (12vdc max 200ma)
13
negative for flashlight input 24vdc (9+ / 13-)
TErMINAL BOArD J4
sECUrITY LOCK
Connector for manual release security (connected in the
factory - Do not reMove !)
TErMINAL BOArD J5
sW
Connector dedicated to the programming in the factory.
DO NOT TOUCH THE JUMPEr WHICH Is IN THE POsITION
INDICATED IN THE fIGUrE!
TErMINAL BOArD J6
EXP. 12V
eXPanDer board connector (vrs. 12/24v code aCG5471).
CONNECTOr J7
rADIO
radio receiver with a 24vdc input connector.
CONNECTOr J8
BATTErY CHArGEr
Battery charger board connector (code aCG4661).
CONNECTOr J9
L1 - N
Input 230 vac 50/60 Hz (external to the board).
LED sIGNALINGs
DL1 - (red) - encoder working check
DL2 - (red) - Stop contact (nC)
G
B