natural gas supply from home
quick release connector
natural gas hose
ensure quick release connector is fully
connected onto natural gas hose
side burner valve
connection
remove extra adaptor
(not required in assembly)
NATURAL GAS CONNECTION
Connect a manual shut-off valve to gas supply line. Apply sealing compound or
pipe thread tape of the type resistant to the action of natural gas on all male
pipe threads. Attach to side burner valve. Connect the other end of the flex hose
to manual shut-off valve through a nipple.
NATURAL GAS HOSE ASSEMBLY
CAUTION:
During any high-pressure testing of the gas supply
piping system at test pressures in excess of ½ psi
(3.5 kPa),
your gas grill and its individual shut-off
valve must be disconnected from the gas supply
piping system.
During any low pressure testing of the gas supply
piping system at test pressures equal to or less than
½ psi (3.5 kPa),
your gas grill must be isolated from
the gas supply piping system by closing its individual
manual shut-off valve.