128-7853
10 of 16
10
The Light Blue wire can be used to accommodate the following situations:
A. Shock Sensor By Pass:
B. Additional Ignition Output:
C. GM VATS Key Override:
Green w/ Black Trace Wire:
250 mA Latched Channel 4 Output
The Green w/ Black Trace wire supplies a 300 mA switched output whenever channel four of
the receiver is accessed. Pressing the pre-programmed transmitter button(s) will access
channel four and will remain active, for up to 20 seconds, as long as the transmitter button(s)
is held. This is a low current output and must be connected to a relay to supply power to the
device you intend to control. Connect Green w/ Black Trace wire to terminal #86 of a VF45F11
P&B relay or equivalent. Connect terminal #85 of the relay to a fused + 12 volt source. Connect
the common, normally open, and normally closed contacts of the relay to perform the selected
function of the channel 4 output.
NOTE:
This wire also can be used for defrost activation as dictated by the setting of feature # 1
of Bank 3. Anytime the vehicle is running under control of the Remote Start and Channel 4 is
activated, then dependent on the selection of this feature, Green/Black will be activated as a
pulse for 1 second, or for 10 minutes. Note this wire will not operate when the vehicle is running
under the power of the ignition key, only while under the control of the remote start or if not used
for defrost then an output will occur as indicated above.
Black w/ White Trace Wire :
250 mA Horn Output
The black w/ white trace wire is provided to beep the vehicle’s horn. This is a transistorized
low current output, and should only be connected to the low current ground output from the
vehicle’s horn switch. If the vehicle uses a + 12 VDC horn switch, then connect the black w/
white trace wire to terminal 86 of the AS 9256 relay ( or an equivalent 30 Amp automotive
relay ),and connect relay terminal 85 to a fused + 12 VDC battery source. Connect relay
terminal 87 to the vehicle’s horn switch output, and connect relay terminal 30 to a fused +
12 VDC battery source.
Green w/ White trace Wire:
Entry Illumination Ground Output
This wire provides a 30 second ground output (250 mA Max.) whenever the remote is used to
disarm the alarm or to unlock the doors and provides a continuous pulsed output whenever
the alarm is triggered. This wire should be connected to an external relay and wired to the
vehicles interior entry lighting whenever the optional Interior Illumination circuit is desired.
Red/Black Wire:
Ignition 3 Output
This wire provides a 200mA (-) ground output that becomes active 4 seconds before the
remote start unit initialize, and remains ground 4 seconds after the remote start unit shuts
down.
Summary of Contents for APS-920
Page 12: ...128 7853 12 of 16 12 ...