DBP SERIES SCISSOR LIFTS
sibility of injury. Lifts with oversize table tops require
special handling (See Section 5, Maintenance).
WARNING!
⇑
Do not perform any repair work on lifts if there
is a load on the platform or with the table in a
raised position.
⇑
All personnel must stand clear of the lift when
the lift is in motion.
⇑
Do not put hands or feet under the lift table.
⇑
Do not work under the table without securing the
lift with supplied safety chocks.
⇑
Do not stand, sit or climb on the lift.
⇑
Do not use the lift on soft, uneven or unstable
surfaces.
⇑
Do not exceed the load capacity.
⇑
Do not place a load on a moving lift.
⇑
Place loads in the center of the table and secure
loads properly.
S E C T I O N 3
INSTALLATION
A. UNCRATING AND INSPECTION
:
Upon receipt of the
DBP Series DC Electric Scissor
Lifts
, inspect the equipment completely to determine if
there is any shipping damage, and that the lift is com-
plete. Presto Lifts Inc. tests and inspects every piece of
equipment prior to shipment. If damage is apparent, a
freight claim must be filed with the freight company. Do
Not use the lift if there appears to be any damage. With
the lift in a collapsed position, check the following:
CAUTION!
Lifts with oversize table tops must not be over ex-
tended since doing so may disassociate the cylinder
base from its socket. (See Section 5, Maintenance).
⇑
Check for signs of damage especially to the elec-
trical and hydraulic components.
⇑
Check all connections for tightness.
⇑
Check for any bent or damaged metal parts.
⇑
Check base frame for flatness.
CAUTION!
When moving the lift, do not attempt to pick it up
by the table top. The lift should be picked up by its
base only.
S E C T I O N 1
INTRODUCTION
This manual attempts to provide all of the information
necessary for the safe and proper installation, operation
and maintenance of Presto Lifts Inc.'s DBP Series DC
Electric Scissor Lifts. It is important that all personnel
involved with the installation, maintenance or opera-
tor of the scissor lift read this manual. Where unique
situations arise, that are not covered in this manual call
Presto Lifts for further instructions. Additional manuals
are available upon request or on our web site at www.
prestolifts.com.
The scissor lift has a nameplate that provides the load
capacity ratings, serial number and model identifica
-
tions. Please refer to these numbers when ordering parts
or requesting further information.
The Presto Lifts
DBP Series DC Electric Scissor
Lifts
are designed for lifting, lowering and position-
ing a variety of loads. WHERE UNIQUE SITUA-
TIONS ARISE, THAT ARE NOT COVERED IN THIS
MANUAL, CALL PRESTO LIFTS FOR FURTHER
INSTRUCTIONS.
The
DBP Series DC Electric Scissor Lifts
is designed
for in plant/nonhazardous location use only. These units
are not for personnel lifting.
S E C T I O N 2
SAFETY
The DBP Series DC Electric Scissor Lifts are very
powerful lifts capable of doing large amounts of work.
They contain scissor legs, that are hydraulically actuated
and are capable of causing serious injury or damage if
adequate precautions are not taken.
DO NOT INSTALL OR OPERATE THESE LIFTS
WITHOUT CAREFULLY READING THIS MANU-
AL. In order to provide for the safe operation of these
scissor lifts, Presto Lifts Inc. has identified certain haz
-
ards that may occur during the installation, maintenance
and use of these lifts.
For safety reasons the standard
DBP Series DC Electric Scissor Lifts are designed
to be serviced or repaired in the lowered position.
If performed properly, this will greatly reduce the pos-