Presto-ECOA Lifts AX, AXR, AXS & AT Series and AL Series
Page 11
S E C T I O N 5
MAINTENANCE
Generally, the AX/AXR/AXS/AXT/AT and AL Series of pneumatic scissor lifts will require little main
-
tenance. However, routine maintenance and inspection will minimize cost of repairs and hazardous
conditions.
WARNING!
Never go under or service lift with a load on the table or with the scissor mechanism
loaded. If possible, service the lift in a down position.
WARNING!
If the pneumatic system requires repairs, shut off and lock out the air supply. Purge the
system of any pressure before beginning any repairs.
A. MAINTENANCE CHOCKS
The AX, AXR, AXS, AXT, AT Series and the AL Scissors Lifts are designed to be maintained and serviced
in a raised position. Maintenance chocks are provided for locking the lift in a raised position. Refer to
Figure 2.
1. Chock Installation
a) Completely remove any load from the lift platform.
b) Raise the lift to its full height.
c) Slip the maintenance chock (A) in place and insert the locking pin (B).
d) Lower the lift until the leg roller comes in contact with the maintenance chock.
e) Check that the maintenance chock is securely in place.
f) Release all air pressure from the lift. The chock is now supporting the lift.
2. Chock Removal
a) Raise the lift to its full height.
b) Remove the locking pin (B) and the maintenance chock (A).
c) Lower the lift.
Figure 3: Pneumatic connections