background image

14

GEN-10P

GEN-25P

26033

26034

 www.truper.com

09-2019

ENGLISH

Warranty Policy

Model

Code

Brand

Delivery date:

This product, its parts and components have a one year warranty against defects in its 
manufacture, operation and workmanship, except when: the product has been used in conditions 
other than those recommended, or has not been operated according to the instructions, or has 
been altered or repaired by personnel not authorized by                          . In order to make the 
warranty valid or to purchase components and spare  parts, you must present the product and its 
proof of purchase at Av. San Isidro #110, Col. Industrial San Antonio, ALC. Azcapotzalco, C.P. 
02760, CDMX, Mex. or at the store where you bought it, or at a                           service center 
listed in the attached warranty policy and/or at www.truper.com. Transportation costs resulting 
from compliance of this warranty will be covered by                          . For questions or comments, 
call 800-690-6990.
Imported by:  

Truper, S.A. de C.V. 

, Parque Industrial #1, Jilotepec, Edo. de Méx., 

Méx. C.P. 54240, Made in China

Stamp of the business:

1

YEAR

Warranty policy

DRAFT 

DRAFT 

DRAFT

Summary of Contents for 26033

Page 1: ...EN 25P 26033 26034 2 9 Hp 6 5 Hp Motor GEN 10P Motor GEN 25P CAUTION Read this manual thoroughly before using the tool ENGLISH ESPAÑOL Manual Power Generator Model Code Applies for D R A F T D R A F T D R A F T ...

Page 2: ...ng Authorized Service Centers Póliza de Garantía ENGLISH Contents Keep this manual for future references The illustrations in the manual are for reference only May be different from the real tool To gain the best performance longer tool life span make the warranty valid if needed and to avoid risks or fatal injuries please read and understand the entire manual prior to using the tool CAUTION D R A...

Page 3: ...periods of time Empty the gasoline tank start the motor and leave it running until the fuel and carburetor lines are empty The next season use fresh gasoline Never pour into the gasoline tank motor or carburetor cleaning liquids because it can result in permanent damage WARNING V 91L4 0 3 mm 2 L 20 A Winding c c Winding Spark Plug Black Brown 1 0 mm2 Brown Red 1 0 mm2 Red 1 0 mm2 Red 1 0 mm2 Overl...

Page 4: ...tor could damage the equipment or cause severe personal injuries to the operator Do not overreach Keep both feet perfectly set on the ground and keep good balance at all times These measures lead to better controlling the tool in unexpected situations Wear proper clothes Do not wear loose clothes or jewelry Keep your hair clothes and gloves away from moving parts Loose clothes jewelry or long hair...

Page 5: ...to account the differences between the power supply and the generator technical specifications Protection against electric shock depends on the circuit breakers are specially homogenized for the generator If the circuit breakers must be replaced go to a Authorized Service Center Alternate current connections within the electric system shall be carried out by a certified electrician complying with ...

Page 6: ...el Tank Meter Air Filter Control and Connection Panel 6 Parts Electric generators made with one cylinder air cooled gasoline motor are a portable electric energy source for recreational use travel or camping for emergencies during blackouts or for domestic use out of range of the power company 12 V Terminals Output Voltage Selector 2 120 V Outlets Control and connection panel GEN 10P GEN 25P 240 V...

Page 7: ...d oil until the level is within the limits in the cap oil measuring rod Replace oil after 50 hours operation or each season In very dusty or dirty conditions it may be necessary to change oil more often Oil Supply A Set the generator in a flat leveled surface Clean and dry the area around the fuel cap Remove the fuel cap Using a funnel slowly fill up the fuel tank up to the lower part of the tank ...

Page 8: ...ting more than one device connect first those using a higher current to start Verify the devices do not exceed longer than 30 minutes the rated current of the generator and that never exceed the maximum output load Turn ON the switch and the breakers If there is an important overload the overload protector will turn OFF It is possible that a marginal overload will not turn OFF the thermal protecti...

Page 9: ...each 1000 feet above 6890 feet above sea level The decrease in power will be more drastic if no adjustments to the carburetor are carried out Consult a Authorized Service Center to make the adjustments Operating in High Altitude CAUTION General review Motor oil Air filter Sediment container Spark plug Valve clearance Fuel tank and strainer Fuel line Fuel tank cap Regular and careful maintenance es...

Page 10: ... cleaned With the motor OFF and ambient temperature close the fuel tap E Remove the sediment container F Clean the interior together with the filter G Leave the filter and container drying completely Verify the washer H is in good conditions Set the sediment container and fuel filter back in place Fuel Filter Oil Change The oil drain cap is set under the motor B Set an adequate container under the...

Page 11: ...uel tank contents Once drained set the filter and sediment container Set under the tank and adequate container to receive gasoline Use a funnel to prevent fuel from spilling Remove the drain bolt D Once the fuel is drained in the container set the drain bolt back and washer Tighten firmly Clean all fuel Spark Plug Before removing the spark plug E clean the area around the spark plug base to preven...

Page 12: ...e oil level is within the minimum and maximum level in the oil measuring rod Verify spark in the spark plug 1 Disconnect the spark plug cable Clean the dust around the spark plug and remove it 2 Connect the cable to the spark plug 3 Turn ON the motor switch 4 Make contact with the lateral electrode of the spark plug with any metallic part of the motor that is free of oil It is important to carry o...

Page 13: ...30 INTERIOR DE PASAJE ROBLEDO COL CENTRO C P 43600 TULANCINGO HGO TEL 775 753 6615 775 753 6616 SUCURSAL GUADALAJARA AV ADOLFO B HORN 6800 COL SANTA CRUZ DEL VALLE C P 45655 TLAJOMULCO DE ZUÑIGA JAL TEL 33 3606 5285 AL 90 FIX FERRETERÍAS AV PASEO DE LA REPÚBLICA 3140 A COL EX HACIENDA DE LA HUERTA C P 58050 MORELIA MICH TEL 443 334 6858 FIX FERRETERÍAS CAPITÁN ANZURES 95 ESQ JOSÉ PERDIZ COL CENTRO...

Page 14: ...order to make the warranty valid or to purchase components and spare parts you must present the product and its proof of purchase at Av San Isidro 110 Col Industrial San Antonio ALC Azcapotzalco C P 02760 CDMX Mex or at the store where you bought it or at a service center listed in the attached warranty policy and or at www truper com Transportation costs resulting from compliance of this warranty...

Page 15: ...digo GEN 10P GEN 25P Este instructivo es para 26033 26034 2 9 Hp 6 5 Hp Motor GEN 10P 2 175 W 4 875 W Motor GEN 25P No utilice el aparato sin leer el instructivo G ARANTI A G A R A N T I A ADVERTENCIA ESPAÑOL ENGLISH D R A F T D R A F T D R A F T ...

Page 16: ...de ser necesario y evitar riesgos o lesiones fatales es fundamental leer y comprender este instructivo por completo antes de usar la herramienta Especificaciones técnicas Requerimientos de combustible Diagrama eléctrico Advertencias generales de seguridad para generadores eléctricos Advertencias de Seguridad para uso de generadores eléctricos Partes Combustible y aceite Puesta en marcha Mantenimie...

Page 17: ...e combustible antes de almacenar el generador por periodos de 30 días o más tiempo Vacíe el tanque de gasolina arranque el motor y déjelo funcionar hasta que las líneas de combustible y el carburador se vacíen La siguiente temporada use gasolina fresca Nunca use dentro del tanque de gasolina productos para limpiar motores o carburadores ya que puede ocasionar daño permanente ADVERTENCIA V 91L4 0 3...

Page 18: ... del generador pueden causar daños al equipo o al operador No sobrepase su campo de acción Mantenga ambos pies bien asentados sobre el suelo y conserve el equilibrio en todo momento Esto permite un mejor control de la herramienta en situaciones inesperadas Vista adecuadamente No vista ropa suelta o joyas Mantenga su pelo su ropa y guantes alejados de las piezas en movimiento La ropa o el pelo suel...

Page 19: ...rencias entre el suministro eléctrico y las especificaciones técnicas del generador La protección contra choques eléctricos depende de que los interruptores de circuito estén homogeneizados especialmente para el generador Si los interruptores de circuito deben ser reemplazados acuda a un Centro de Servicio Autorizado para su reemplazo Las conexiones de corriente alterna dentro del sistema eléctric...

Page 20: ...e de combustible Medidor del tanque de combustible Filtro de aire Panel de control y conexión 6 Partes Los generadores eléctricos con motor a gasolina de un cilindro enfriados por aire son una fuente de energía eléctrica portátil para uso recreativo viajes o campamen tos para emergencia durante apagones o para uso doméstico sin alcance de la compañía de luz Terminales 12 V Selector de tensión de s...

Page 21: ...tre entre los límites de la varilla del tapón Cambie el aceite después de 50 horas de operación o cada temporada En condiciones de mucho polvo o suciedad puede ser necesario hacer el cambio de aceite más a menudo Abastecimiento de aceite A Coloque el generador en una superficie plana y nivelada Limpie y seque el área alrededor de la tapa del combustible Retire la tapa del combustible Con ayuda de ...

Page 22: ...te F en los contactos del panel de conexión Si conecta más de un dispositivo conecte primero los que utilicen una corriente más alta para su arranque Verifique que los dispositivos no excedan la corriente nominal de generador por más de 30 minutos y que nunca excedan la máxima salida de carga Encienda el interruptor y los breakers Si existe una sobrecarga importante el protector de sobrecarga se a...

Page 23: ...iba de 2100 m 6890 pies sobre el nivel del mar La disminución de potencia será más drástica si no se realizan ajustes al carburador Consulte a un Centro de Servicio Autorizado para realizar los ajustes Operación a gran altitud ATENCIÓN Revisión general Aceite del motor Filtro de aire Contenedor de sedimentos Bujía Despeje de válvula Tanque de combustible y colador Línea de combustible Tapa del tan...

Page 24: ...re la llave de combustible E Retire el contenedor de sedimento F limpie su interior junto con el filtro G Permita que el filtro y contenedor se sequen por completo Verifique que el empaque H se encuentre en buenas condiciones y vuelva a colocar el contenedor de sedimentos y el filtro de combustible en su lugar Filtro de combustible Cambio de aceite El tapón de drenaje de aceite se localiza debajo ...

Page 25: ...enido del tanque de combustible Una vez drenado coloque el filtro y el contenedor de sedimentos Coloque debajo del carburador un contenedor adecuado para recibir gasolina y utilice un embudo para evitar que se salpique el combustible Retire el perno de drenaje D Una vez que se ha drenado el combustible en el contenedor coloque de nuevo el perno de drenaje y su arandela apretándolos firmemente Limp...

Page 26: ...egúrese de que el nivel de aceite este entre los limites mínimo y máximo en la varilla Verifique la chispa de la bujía 1 Desconecte el cable de la bujía limpie el polvo alrededor de la bujía y retírela 2 Conecte el cable a la bujía 3 Encienda el interruptor del motor 4 Ponga en contacto el electrodo lateral de la bujía con cualquier parte metálica del motor libre de combustible Es importante reali...

Page 27: ... 304 LOCAL 30 INTERIOR DE PASAJE ROBLEDO COL CENTRO C P 43600 TULANCINGO HGO TEL 775 753 6615 775 753 6616 SUCURSAL GUADALAJARA AV ADOLFO B HORN 6800 COL SANTA CRUZ DEL VALLE C P 45655 TLAJOMULCO DE ZUÑIGA JAL TEL 33 3606 5285 AL 90 FIX FERRETERÍAS AV PASEO DE LA REPÚBLICA 3140 A COL EX HACIENDA DE LA HUERTA C P 58050 MORELIA MICH TEL 443 334 6858 FIX FERRETERÍAS CAPITÁN ANZURES 95 ESQ JOSÉ PERDIZ...

Page 28: ...por personal no autorizado por Para hacer válida la garantía o adquirir piezas y componentes deberá presentar el producto y su comprobante de compra en Av San Isidro 110 Col Industrial San Antonio Alc Azcapotzalco C P 02760 CDMX Méx o en el establecimiento donde lo compró o en algún Centro de Servicio de los enlistados en el anexo de la póliza de garantía y o en www truper com Los gastos de transp...

Reviews: