Starting and Stopping Procedures
126
WARNING
Wear eye protection and remove rings, metal
jewelry and watches with metal bands.
DANGER
The gases given off by batteries while jump
starting are explosive. Do not smoke near
batteries.
DANGER
The battery could rupture or explode if jump
started when the run-down battery fluid is
frozen or if the battery fluid level is low. Check
condition of run-down battery before
attempting to jump start.
CAUTION
Do not let the two vehicles touch. Keep a
walk-through distance between the two
vehicles. Make sure positive (red) and
negative (black) jumper cable clamps do not
touch.
CAUTION
Never connect the jumper cable to the
negative terminal post of the run-down battery.
CAUTION
Do not jump start if a maintenance-free battery
has a yellow test indicator. Have the battery
replaced.
WARNING
Before attempting to jump start, make sure the
parking brake is applied and the transmission
is in neutral (N). Turn off all lights, heaters
and other electrical accessories.
CAUTION
Choose a booster vehicle which produces
comparable amperage as your vehicle.
To jump start, proceed as follows:
1. Remove the protective cap from the booster
block terminal located in the R.H. side
engine compartment;
2. Connect one end of the red jumper cable to
the positive (+) post of the booster power
source. If the good battery is in another
vehicle, that vehicle's engine must be shut
OFF
before connecting;
3. Connect the other end of the same red
jumper cable to the positive (+) terminal on
the booster block;
4. Connect one end of the black jumper cable
to the negative (-) post on the booster power
source;
5. Connect the other end of the same black
jumper cable to the negative (-) terminal on
the booster block; If the good battery is in
another vehicle, start that vehicle's engine;
6. Let the engine run for a few minutes, then
start the vehicle with the run-down battery;
7. Disconnect the jumper cables in reverse
order given in steps 2 through 5;
8. Install protective cap on the booster block
terminal.
NOTE
Jumper cables must be rated at 500 cranking
amperes. If jumper cable length is 20 feet (6
m) or less, use 2/0 (AWG) gauge wires. If
cable length is between 20 to 30 feet (6 to 9
m), use 3/0 (AWG) gauge wires.
BOOSTER BLOCK LOCATION
06623
Summary of Contents for X3-45 2011
Page 1: ...COACH MANUFACTURER OPERATOR S MANUAL X3 45 COACH PA1581...
Page 4: ......
Page 6: ......
Page 10: ......
Page 24: ......
Page 128: ......
Page 134: ......
Page 171: ...Technical Information 165 X3 45 OVERALL DIMENSIONS SIDE ELEVATION 18673...
Page 172: ...Technical Information 166 X3 45 OVERALL DIMENSIONS TOP FRONT AND REAR VIEWS 18674...
Page 182: ......
Page 186: ......
Page 206: ......