SECTION 06B: ELECTRICAL
1
MULTIPLEX ERROR MESSAGES TROUBLE SHOOTING LIST
MID (Message Identification Description)
: Identification of a control unit
PID (Parameter Identification Description)
: Identification of a parameter (value)
PPID (Proprietary Parameter Identification : Unique Identification of a parameter (value)
Description)
SID (Subsystem Identification Description) : Identification of a component
PSID (Proprietary Subsystem Identification : Unique Identification of a component
Description)
FMI (Failure Mode Identifier) : Identification of fault types
MID 188 PSID # 4 A/C Clutch So9 (A52 J1:20)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
output A52 J1:20 but
output not active
A/C clutch
always ON
A52 module failure
Connector C91 corroded
Circuit 77BA shorted to battery
FMI 4
Shorted Low
Output A52 J1:20
shorted to ground
A/C clutch not
working
A52 module failure
Connector C91 corroded
Circuit 77BA shorted to ground
FMI 5
Open Circuit
A52 module does not
detect A/C clutch So9
A/C clutch not
working
A52 module failure
So9 open circuit
Se29 failure
Circuit 77BA open
Circuit 78 open
Circuit ORA2 open
FMI 6
Current
above normal
Output A52 J1:20
internal software fuse
active for overcurrent
A/C clutch not
working
A52 module failure
Connector C91 corroded
Circuit 77BA shorted to ground
A/C clutch resistance value
lower than 5 ohms (7 ohms
expected)
MID 188 PSID # 12 A/C Pres HiSd (A52 J1:13)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage above
normal on A52 J1:13
High side
pressure not
displayed on
dash
A52 module failure
Se23 failure
Connector C91 corroded
Circuit 77-20 shorted to battery
FMI 4
Shorted Low
Voltage below normal
on A52 J1:13
High side
pressure not
displayed on
dash
A52 module failure
Se23 failure
Connector C91 corroded
Circuit 77-20 shorted to ground
FMI 5
Open Circuit
A52 module does not
detect Se23
High side
pressure not
displayed on
dash
A52 module failure
Se23 failure
Circuit 77-20 open
Summary of Contents for X3-45 2016
Page 4: ......
Page 16: ...Section 00 GENERAL INFORMATION PA1593 12 FIGURE 12 METRIC US STANDARD CONVERSION TABLE 00005...
Page 17: ...Section 00 GENERAL INFORMATION 13 PA1593 FIGURE 13 CONVERSION CHART 00006...
Page 18: ......
Page 26: ......
Page 58: ......
Page 72: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 14 7 TORQUE SPECIFICATIONS...
Page 73: ...SECTION 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 15...
Page 74: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 16...
Page 76: ......
Page 96: ......
Page 134: ......
Page 176: ...SECTION 06B ELECTRICAL 38 overcurrent working Circuit 306 shorted to ground...
Page 180: ......
Page 202: ......
Page 205: ...Section 09 PROPELLER SHAFT PA1593 3 FIGURE 1 PROPELLER SHAFT ASSEMBLY 09002...
Page 256: ......
Page 268: ......
Page 295: ...SECTION 16 SUSPENSION PA1593 9 2 5 TORQUE SPECIFICATIONS...
Page 296: ...Section 16 SUSPENSION PA1593 10...
Page 297: ...Section 16 SUSPENSION PA1593 11...
Page 314: ......
Page 380: ......
Page 388: ......
Page 413: ...Section 22 HEATING AND AIR CONDITIONING PA1593 15 FIGURE 18 REFRIGERANT CIRCUIT CENTRAL SYSTEM...
Page 433: ...Section 22 HEATING AND AIR CONDITIONING PA1593 35 FIGURE 36 CENTRAL HEATING SYSTEM COMPONENTS...