SECTION 06B: ELECTRICAL
7
FMI 4
Shorted Low
Output A49 J1:11
shorted to ground
Direct lights not
working
A49 module failure
Direct Lights Relay R6 failure
Circuit 38 shorted to ground
FMI 5
Open Circuit
A49 module does not
detect direct lights
relay R6
Direct lights not
working
A49 module failure
Direct Lights Relay R6 failure
Direct Lights Relay R6 open
circuit
Circuit 38 open
FMI 6
Current
above normal
Output A49 J1:11
internal software fuse
active for overcurrent
Direct lights not
working
A49 module failure
Circuit 38 shorted to ground
MID 188 PSID # 180 Driver Def Fan (A47 J1:1)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
output A47 J1:1 but
output not active
Defroster fans
Mo24 and Mo25
not working
A47 module failure
A24 module failure
Circuit 86 shorted to battery
FMI 4
Shorted Low
Output A47 J1:1
shorted to ground
Defroster fans
Mo24 and Mo25
on full speed
A47 module failure
A24 module failure
Circuit 86 shorted to ground
FMI 5
Open Circuit
A47 module does not
detect Defroster
Speed Ctrl A24
Defroster fans
Mo24 and Mo25
on full speed
A47 module failure
A24 module failure
Circuit 86 open
FMI 6
Current
above normal
Output A47 J1:1
internal software fuse
active for overcurrent
Defroster fans
Mo24 and Mo25
on full speed
A47 module failure
A24 module failure
Circuit 86 shorted to ground
MID 188 PSID # 16 Driver heat Sol (A46 J1:6)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
output A46 J1:6 but
output not active
No heat in
driver’s area
A46 module failure
Connector C4 corroded
Circuit 50 shorted to battery
FMI 4
Shorted Low
Output A46 J1:6
shorted to ground
Full heat in
driver’s area
A46 module failure
Connector C4 corroded
Circuit 50 shorted to ground
FMI 5
Open Circuit
A46 module does not
detect Driver Heat
Solenoid So8
Full heat in
driver’s area
A46 module failure
So8 open
Circuit 50 open
FMI 6
Current
above normal
Output A46 J1:6
internal software fuse
active for overcurrent
Full heat in
driver’s area
A46 module failure
Connector C4 corroded
Circuit 50 shorted to ground
Driver heat solenoid So8 Low
resistance value (expected
value ± 40 ohms)
Summary of Contents for X3-45 2016
Page 4: ......
Page 16: ...Section 00 GENERAL INFORMATION PA1593 12 FIGURE 12 METRIC US STANDARD CONVERSION TABLE 00005...
Page 17: ...Section 00 GENERAL INFORMATION 13 PA1593 FIGURE 13 CONVERSION CHART 00006...
Page 18: ......
Page 26: ......
Page 58: ......
Page 72: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 14 7 TORQUE SPECIFICATIONS...
Page 73: ...SECTION 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 15...
Page 74: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 16...
Page 76: ......
Page 96: ......
Page 134: ......
Page 176: ...SECTION 06B ELECTRICAL 38 overcurrent working Circuit 306 shorted to ground...
Page 180: ......
Page 202: ......
Page 205: ...Section 09 PROPELLER SHAFT PA1593 3 FIGURE 1 PROPELLER SHAFT ASSEMBLY 09002...
Page 256: ......
Page 268: ......
Page 295: ...SECTION 16 SUSPENSION PA1593 9 2 5 TORQUE SPECIFICATIONS...
Page 296: ...Section 16 SUSPENSION PA1593 10...
Page 297: ...Section 16 SUSPENSION PA1593 11...
Page 314: ......
Page 380: ......
Page 388: ......
Page 413: ...Section 22 HEATING AND AIR CONDITIONING PA1593 15 FIGURE 18 REFRIGERANT CIRCUIT CENTRAL SYSTEM...
Page 433: ...Section 22 HEATING AND AIR CONDITIONING PA1593 35 FIGURE 36 CENTRAL HEATING SYSTEM COMPONENTS...