SECTION 06B: ELECTRICAL
9
MID 188 PSID # 28 Driver Sensor (A55 J1:1)
Type of
fault:
FMI
Description:
Fault Condition:
Possible Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage above
normal on A55 J1:1
Driver temperature not
displayed on HVCA
module. Driver is full heat
with set point above 70°F
and full A/C with set point
below 70°F.
A55 module failure
Se21 failure
Circuit ANA-89
shorted to battery
FMI 4
Shorted Low
Voltage below normal
on A55 J1:1
Driver temperature not
displayed on HVCA
module. Driver is full heat
with set point above 70°F
and full A/C with set point
below 70°F.
A55 module failure
Se21 failure
Circuit ANA-89
shorted to ground
FMI 5
Open Circuit
A55 module does not
detect Driver
Temperature Sensor
Se21
Driver temperature not
displayed on HVCA
module. Driver is full heat
with set point above 70°F
and full A/C with set point
below 70°F.
A55 module failure
Se21 failure
Circuit ANA-89 open
MID 188 PSID # 26 Passenger Sensor (A54 J1:13)
Type of
fault:
FMI
Description:
Fault Condition:
Possible Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage above
normal on A54 J1:13
Following message
appears on the DID:
PSID 26 PASS. SENSOR
{psid +26, 188, pass.
sensor}
Out of range
A54 module failure
Se25 failure
Circuit ANA-86
shorted to battery
FMI 4
Shorted Low
Voltage below normal
on A54 J1:13
A54 module failure
Se25 failure
Circuit ANA-86
shorted to ground
FMI 5
Open Circuit
A54 module does not
detect Passenger
Temperature Sensor
Se25
A54 module failure
Se25 failure
Circuit ANA-86 open
MID 188 SID # 64 Drv air Trap (A44 J1:2)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High Voltage present on
output A44 J1:2 but
output not active
Dash damper
not moving
A44 module failure
Dash Damper Mo3 failure
Connector C72 corroded
Circuit 68A shorted to battery
FMI 4
Shorted Low
Output A44 J1:2
shorted to ground
Dash damper
not moving
A44 module failure
Dash Damper Mo3 failure
Connector C72 corroded
Circuit 68A shorted to ground
FMI 6
Current
above normal
Output A44 J1:2
internal software fuse
active for overcurrent
Dash damper
not moving
A44 module failure
Connector C72 corroded
Circuit 68A shorted to ground
Summary of Contents for X3-45 2016
Page 4: ......
Page 16: ...Section 00 GENERAL INFORMATION PA1593 12 FIGURE 12 METRIC US STANDARD CONVERSION TABLE 00005...
Page 17: ...Section 00 GENERAL INFORMATION 13 PA1593 FIGURE 13 CONVERSION CHART 00006...
Page 18: ......
Page 26: ......
Page 58: ......
Page 72: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 14 7 TORQUE SPECIFICATIONS...
Page 73: ...SECTION 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 15...
Page 74: ...Section 04 EXHAUST AND AFTERTREATMENT SYSTEM PA1593 16...
Page 76: ......
Page 96: ......
Page 134: ......
Page 176: ...SECTION 06B ELECTRICAL 38 overcurrent working Circuit 306 shorted to ground...
Page 180: ......
Page 202: ......
Page 205: ...Section 09 PROPELLER SHAFT PA1593 3 FIGURE 1 PROPELLER SHAFT ASSEMBLY 09002...
Page 256: ......
Page 268: ......
Page 295: ...SECTION 16 SUSPENSION PA1593 9 2 5 TORQUE SPECIFICATIONS...
Page 296: ...Section 16 SUSPENSION PA1593 10...
Page 297: ...Section 16 SUSPENSION PA1593 11...
Page 314: ......
Page 380: ......
Page 388: ......
Page 413: ...Section 22 HEATING AND AIR CONDITIONING PA1593 15 FIGURE 18 REFRIGERANT CIRCUIT CENTRAL SYSTEM...
Page 433: ...Section 22 HEATING AND AIR CONDITIONING PA1593 35 FIGURE 36 CENTRAL HEATING SYSTEM COMPONENTS...